Effect of coiling in a cochlear model.
Abstract
Transformation of the three-dimensional equations of fluid motion into cylindrical coordinates allowed analysis of a coiled cochlear model by the WKB technique. The model includes a single transverse mode of basilar membrane deflection and inviscid fluid. The results calculated using realistic parameters for the guinea pig show no significant difference in the basilar membrane amplitude and phase between the straight and coiled models. Some differences exist in the fluid pressure found in the scala. The conclusion is that the macromechanical response is not significantly affected by coiling.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
C R Steele, J G Zais. 1985. Effect of coiling in a cochlear model.. https://doi.org/10.1121/1.391935