Does drill noise during mastoid surgery affect the contralateral ear?

Abstract

Drill-generated noise during chronic ear surgery, as well as surgical trauma, has been incriminated as a cause of sensorineural hearing loss in the operated ear. The contralateral ear is subjected to the drill noise but is spared the surgical trauma. Sixty-two patients who had undergone different mastoid operations served as the basis for this study. The average drilling time during surgery was 45 minutes. Sound pressure levels did not exceed 84 dB in the operated ear and 82 dB in the contralateral ear. Though some sensorineural hearing loss was found in the operated ear in fourteen patients, no changes in hearing were found in the contralateral ear. It is suggested that there is no damage exclusively due to the drill noise during mastoid surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Man, I Winerman. 1985. Does drill noise during mastoid surgery affect the contralateral ear?. https://pubmed.ncbi.nlm.nih.gov/4025532/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Should we aspirate middle-ear effusions prior to insertion of ventilation tubes?

BACKGROUND: Routine aspiration of middle-ear effusions prior to ventilation tube (grommet) insertion is practised by many surgeons. It has been suggested that removing the fluid from the middle ear improves immediate post-operative hearing levels and reduces the chance of the ventilation tube becoming obstructed. The potential adverse effects of applying suction to the middle ear include acoustic trauma and an increased risk of tympanosclerosis and otorrhoea. We undertook a review of the literature in order to determine the benefits or side effects associated with middle-ear aspiration prior to ventilation tube insertion. OBJECTIVES: To compare clinical outcomes associated with aspirating versus not aspirating the middle ear prior to ventilation tube insertion. METHODS: The Cochrane ENT group trials register, DARE, the Cochrane central register of controlled trials (CENTRAL), MEDLINE (1960-2005) and EMBASE (1960-2005) were searched using relevant terms. Reference lists of selected studies were scanned for additional research material. RESULTS: Seven studies were identified, of which three fitted the inclusion criteria of our review. Current evidence suggests that aspiration of middle-ear effusions prior to insertion of ventilation tubes is not associated with any improvement in clinical outcome, in terms of post-operative hearing levels, otorrhoea or rates of blockage of ventilation tubes. Significantly increased rates of tympanosclerosis were observed in one study and the development of acoustic trauma was observed; however, no significant association was confirmed. Although more research is needed, there is no evidence that aspiration of middle-ear effusion prior to grommet insertion confers any advantage.

Hearing Loss, Noise-Induced↗

Design of optimal noise hazard control strategy with budget constraint.

An analytical design procedure to determine optimal noise hazard control strategies for industrial facilities is presented. Its objective is to determine a set of appropriate noise controls to eliminate or reduce noise levels so that workers' daily noise exposure does not exceed a permissible level. From a given noise control budget, engineering controls will be firstly implemented, followed by administrative controls, and then the use of hearing protection devices. Six optimization models are developed and sequentially applied to select appropriate noise controls without exceeding the budget. Numerical examples are presented to demonstrate the application of the proposed design procedure.

Hearing Loss, Noise-Induced↗