PubMed HealthSearch

PubMed · 4032109

Workshop on the bone-joint implant interface.

Abstract

A workshop on the bone-implant interface, as related to loosening of total joint implants, was held in Chicago on September 14-16, 1983. More than 60 orthopaedic clinicians and researchers and basic connective tissue biologists met to review problems and potential solutions to joint implant loosening. The following is a synopsis of the presentations and discussions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J L Lewis, J O Galante. 1985. Workshop on the bone-joint implant interface.. https://doi.org/10.1002/jor.1100030315

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Study of polymerization of acrylic bone cement: effect of HEMA and EGDMA.

The polymerization reaction of standard surgical Simplex-P radiopaque bone cement was investigated by differential scanning calorimetry to determine the influence of hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) on the polymerization reaction. From the kinetic analysis, the polymerization reaction of the modified acrylic bone cement was found to be approximately a first-order reaction. The reaction rate constants (k) were determined. It was found that the effects of HEMA and EGDMA contents on the rate and the heat of polymerization can be explained by the frequency factor and the activation energy. An increase in HEMA content tends to result in an increase in the values of both frequency factor and activation energy, whereas an increase in EGDMA content tends to induce a decrease in the frequency factor and activation energy.

Bone Cements

Response of human osteoblasts to polymethylmetacrylate In vitro.

The effects of a polymethylmetacrylate (PMMA) powder with a diameter between 0.5 and 25 mu m have been studied in vitro on several human osteoblast populations obtained from different sources. Parameters of cell activity such as cell growth, collagen synthesis, osteocalcin, and interleukin-6 (IL-6) production have been evaluated. Cell proliferation and collagen synthesis were inhibited after exposure to bone cement, whereas osteocalcin and IL-6 production were stimulated. These results suggest that PMMA particles could affect osteoblast activity in a way that could contribute, together with other factors, to periprosthetic osteolysis through two different pathways: a reduced periprosthetic bone formation due to the reduced osteoblast proliferation and collagen synthesis, and an osteoblast-mediated activation of osteoclastic bone resorption as suggested by the increased osteocalcin and IL-6 synthesis. In fact, osteocalcin has been demonstrated to have a role in osteoclast recruitment to bone surfaces, and IL-6 is known to induce osteoclastogenesis and to directly stimulate bone resorption.

Bone Cements

[Intrafemoral pressure measurement in different cement removal procedures during hip prosthesis replacement operations--experimental study with cadaver femora].

During primary hip arthroplasty an increase in intramedullary pressure (IMP) of up to 1000 mm Hg can be observed. As a result of this increased intrafemoral pressure, intramedullary constituents can pass into the venous circulation creating a risk of fat embolism syndrome (FES). In the present experimental study on 9 femora obtained from human corpses, we investigated the question as to whether various methods of cement removal during total hip revision arthroplasty are also associated with increased intramedullary pressure and a risk of FES. The IMP was recorded with a standardized experimental set-up during removal of cement from the proximal and distal regions, including removal of the cement "tip" and the intramedullary plug. The methods employed for this purpose included the osteotome and mallet, a compressed air powered chisel, and a modified intracorporal lithotripter. All the methods induced fluctuations in the IMP the highest values being recorded for the conventional method using the osteotome and mallet (45 mm Hg) and the lowest values for the intracorporeal lithotripter (7.5 mm Hg). Working on the distal cement caused higher fluctuations in comparison with the proximal region. The study failed to reveal any increase in mean IMP, and all measured values were in the low pressure range (considerably below 150 mm Hg). While there seems to be no apparent risk of an FES developing during removal of cement, careless manipulation of the distal cement plug may result in higher intrafemoral pressures--above 150 mm Hg--thus increasing the risk of a fat embolism syndrome.

Bone Cements