Membrane structural domains. Resolution limits using diphenylhexatriene fluorescence decay.

Abstract

Measurement of multiple fluorescence decay times of 1,6-diphenyl-1,3,5-hexatriene (DPH) in membranes can in principle be used to investigate structural domains of lipid bilayers. To assess the feasibility of this approach using phase and modulation techniques, we reduced experimental errors specifically associated with performing these measurements on membrane suspensions (probe self-quenching, background fluorescence, turbidity-induced artifacts) and determined empirically the level of precision thereby obtainable. Next we used these precision limits in theoretical calculations to conclude that the ratio of two coexisting decay times must exceed 1.3 if they are to be resolved with reliable accuracy. To demonstrate that such resolutions could be accomplished experimentally in membrane suspensions, three approaches were taken. First, the fluorescence decay of aqueous quinine sulfate quenched by chloride ion was resolved from that of membrane-associated DPH as long as the lifetime ratios of these two fluorophores exceeded the predicted value. Second, populations of DPH-containing lipid vesicles with single (or nearly single) decay times were mixed together, and when there were only two major lifetime components that differed by more than 30%, the resulting heterogeneous fluorescence could be resolved into the two expected lifetime components. Finally, DPH fluorescence decay measurements were correlated with phase behavior in well-characterized lipid systems, revealing a short lifetime component of DPH fluorescence associated with gel-phase lipid vesicles. From these studies, we conclude that only in special cases can co-existing gel and fluid phases be resolved by means of DPH lifetime heterogeneity, within the limits of precision defined herein.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D A Barrow, B R Lentz. 1985. Membrane structural domains. Resolution limits using diphenylhexatriene fluorescence decay.. https://doi.org/10.1016/s0006-3495(85)83775-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Phosphorylated 1,6-diphenyl-1,3,5-hexatriene.

A lipophilic dye consisting of a (1E,3E,5E)-1,6-diphenyl-1,3,5-hexatriene (DPH) fluorophore attached to a phosphate diester was prepared, and its fluorescence behavior in different solvent systems and in a liposomal membrane bilayer was examined. The key step in the synthesis of the functionalized end of the dye is a Sonogashira coupling of protected iodophenol with propargyl alcohol; the remaining phenyl ring and double bonds of the all-trans polyene core arise from a Wittig reaction with trans-cinnamaldehyde. Like DPH itself, the emission intensity of its phosphorylated derivative is quenched in polar media.

Diphenylhexatriene↗

Correlation of the thermal stability of phospholipid-based emulsions and the microviscosity measurements using fluorescence polarization.

The fluorescence polarization technique was used to measure the microviscosity of a series of phospholipid-based emulsions. Fourteen different oil-in-water emulsions containing 20% medium chain length triglycerides, various concentrations and types of phospholipids, and 2.2% glycerin were prepared by microfluidization and pH-adjusted to 4.0 or 7.4. Microviscosity was measured by determining the anisotropy of a fluorophore probe (1,6-phenyl 1,3,5-hexatriene) which was found to obey Perrin's equation as has been previously reported for liposomes and membrane bilayers. Moreover the method was validated by comparing viscosities of phospholipid-oil mixtures measured by rheometry and fluorescence polarization. The viscosities determined by fluorescence polarization were within 6% of the values obtained by classic rheometry. Emulsions were also subjected to thermal stress at 121 degrees C. The droplet growth rate was estimated by measuring the time-dependent mean droplet diameter using photon correlation spectroscopy. The logarithm of the droplet growth rate was found to be directly proportional to the interfacial rigidity (i.e., the inverse microviscosity) which suggested that coalescence rather than molecular diffusion is the primary mechanism of droplet growth under these conditions of thermal stress.

Diphenylhexatriene↗

Quantitative determination of fat emulsion using 1,6-diphenyl-1,3,5-hexatriene as fluorescence probe: application to the compounding of all-in-one parenteral nutrition admixtures.

The potential contamination of binary bags by traces of fat emulsion stemmed from ternary bags prepared just before, led us to determine traces of lipids into the line set of the automated compounder MM23. Diphenylhexatriene (DPH) was chosen as fluorescence probe due to its strong fluorescence enhancement in a lipid environment. Optimization of experimental conditions (i.e. DPH amounts, pH of fat emulsion samples, ultrasounds use, light, temperature and contact duration) for fluorescence measurement and validation of analytical method were performed. This method was linear over 0.5-8.0 mg l(-1) (r=0.999) of fat emulsion. The intra-day and inter-day precisions were inferior to 2% for the 2.0 and 8.0 mg l(-1) standards. Under optimized conditions, the detection limit and quantitation limit were 0.10 and 0.29 mg l(-1) of lipids respectively. Compared to the colorimetric method using sodium dichromate, it is at least 100 times more sensitive. The proposed method permitted to rapidly measure fat emulsion traces in automated compounder line set for parenteral nutrition solutions and thus, to assess the risk of contamination of binary bags by lipids. At last, this method was shown to be conveniently applied to the analysis of fat emulsion in the final total parenteral nutrition bag.

Diphenylhexatriene↗