PubMed Health⌕ Search

PubMed · 4054060

Video endoscopy. Fundamentals and problems.

Abstract

The video system represents a new endoscopic technique with major advantages, some of which point the way into the future. This system permits a large number of persons to participate directly in the examination. Documentation is more comprehensive and more reliable, and pathological processes can be observed with the aid of video tape recordings. It is to be expected that the optical elements of the video endoscope will become smaller, while the instruments will become longer. Since there is no loss of light with these endoscopes, it would appear possible that they will make the entire small bowel accessible to inspection. Compared with conventional standards, the colour quality on the video monitor screen, in particular in the red range, and of the video photograph still leaves something to be desired. User-friendly equipment provided with an automatic colour adaption facility, is required. The good thing about the future is, of course, that it comes slowly - and this applies to video endoscopy, too. Since July, 1984, our department has been acquiring experience with the video endoscope manufactured by the firm of Welch Allyn, New York, and, in the meantime, we have examined 97 patients with this system, 80 in the upper, 17 in the lower gastrointestinal tract. The heart of the video endoscope is a light-sensitive microprocessor silicon chip, roughly 4 X 4 mm in size, which acts like a miniature television camera. Properly, it is termed a charge coupled device chip (CCD chip). Utilizing the crystalline structure of the silicon chip, and its property for thermal oxidation, such electronic components as diodes, capacitors and resistors are integrated onto it.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Demling, H J Hagel. 1985. Video endoscopy. Fundamentals and problems.. https://doi.org/10.1055/s-2007-1018491

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Training with simulation improves residents' endovascular procedure skills.

BACKGROUND: Endovascular procedure simulators are now commercially available and in use for physician training. The purpose of this study was to evaluate the role of simulation-based training in vascular surgery residencies. METHODS: Residents from vascular surgery programs in a five-state area were invited to participate in a series of 2-day endovascular training programs that used a high-fidelity endovascular procedure simulator (SimSuite; Medical Simulation Corporation, Denver, Colo), didactic instruction, computer-based training, and tabletop procedure demonstrations. The curriculum covered arteriography and intervention for treatment of aortoiliac, renal, and carotid artery disease. Nine residents participated, with one to three per training session. Each completed an average of 9.5 simulated endovascular cases. Performance on a standardized TransAtlantic Inter-Society Consensus B iliac angioplasty/stenting case was used to assess endovascular skills and knowledge at the beginning of the training program, and this was repeated at the completion of the training. Performance metrics were measured by the simulator, faculty observed trainees' performance of simulated cases, and trainees provided their evaluations of the usefulness of the simulation experiences. RESULTS: Endovascular procedural skills on the standardized iliac intervention case improved after completion of the training program. Compared with performance early on day 1, performance improved (P < or = .05; paired t test): total procedure time decreased 54%, volume of contrast decreased 44%, and fluoroscopy time decreased 48% (mean change from baseline). Selection of angioplasty balloon catheters and stents was improved, and the average number of catheters used and stents deployed decreased, although this did not reach statistical significance. Faculty observation allowed identification of shortcomings of knowledge and skills, including common problems with selection of catheter, balloon, and stent sizes; correct positioning of the sheath; and intraprocedural monitoring. Postcourse evaluations indicated support for the use of simulation in vascular surgery residents' endovascular training. CONCLUSIONS: Training with a simulator, incorporated into an individual or small group learning session, offers a means to learn and realistically practice endovascular procedures without direct risk to patients, with measurable improvements in key performance metrics. How simulation training affects subsequent clinical performance has yet to be established.

Endoscopy↗

Intraoperative surgical navigation for endoscopic sinus surgery: rationale and indications.

PURPOSE OF REVIEW: The present review discusses the rationale and indications for image-guided surgery through a critical discussion of registration concepts as well as clinical reports. RECENT FINDINGS: The surgical navigation accuracy achieved by commercially available image-guided surgery systems is best reported as target registration error. Clinically achievable target registration error is probably in the 1.5-2.0 mm range. Dry lab studies of registration serve to highlight the principles of registration, the process through which image-guided surgery systems calculate the one-to-one mapping relationship between the preoperative imaging data and the intraoperative surgical volume. Reports on image-guided surgery have highlighted its usefulness in primary and revision endoscopic sinus surgery, osteoplastic frontal sinusotomy, transsphenoidal hypophysectomy, endoscopic cerebrospinal fluid leak repair and endoscopic pterygomaxillary fossa biopsy. Both three-dimensional computed tomography angiography and computed tomography-magnetic resonance fusion images have been incorporated into IGS for advanced minimally invasive endoscopic skull base procedures. The American Academy of Otolaryngology-Head and Neck Surgery policy statement accurately summarizes the current consensus for image-guided surgery applications. SUMMARY: Image-guided surgery has emerged as an important technology, which both general otolaryngologists and subspecialty rhinologists can employ for a wide variety of procedures.

Endoscopy↗