[Relationship between nystagmus and utricular function].

Abstract

The horizontal neck nystagmus arising in response to angular acceleration was recorded electromyographically in pigeons (Columba livia). After bilateral section of the utricular nerves (Roumuli utriculi) the nystagmic reactions to the right and to the left remained symmetrical although they were delayed when compared to the reactions of intact animals. Unilateral section of the utricular nerves caused asymmetric reactions from the semicircular canals: the nystagmus toward the dissected nerve was delayed to a greater extent than that toward the intact nerve.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Iu K Stolbkov. [Relationship between nystagmus and utricular function].. https://pubmed.ncbi.nlm.nih.gov/4068649/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Common modulation of motor unit pairs during slow wrist movement in man.

1. The activity of 36 pairs of single motor units were recorded with intramuscular wire electrodes from m. extensor carpi radialis while subjects performed slow wrist extension and flexion movements. Periods of steady position holding were interposed between movements. 2. The discharge trains from pairs of motor units were analysed statistically in the time and frequency domains. During extension movements, when the muscle recorded from was the agonist, coherence between motor units was significant below 12 Hz, with a peak at 6-12 Hz in 30 of 36 pairs (83 %). The magnitude of coherence decreased during position holding compared to movements in 26 pairs, while the difference in average firing rate was small. 3. During movements, but not during position holding, coherence estimates between single motor units and acceleration showed a significant peak at 6-12 Hz in 56 out of 62 motor units, suggesting that a modulation of motor unit discharge contributed to angular acceleration at these frequencies. Common motor unit modulation was present at 3 Hz as well, although the coupling between motor unit activity was weaker than at 6-12 Hz. 4. It is concluded that a 6-12 Hz common modulation of agonist motor units is a distinguishing feature of slow voluntary wrist movements, extending the previously established notion of an 8-10 Hz rhythmic organization of slow finger movements to more proximal limb segments. It is suggested that the 6-12 Hz input is specific for movements and is normally absent or much weaker during steady maintenance of position or force.

Acceleration

An assessment of human performance in stabbing.

Stab-resistant body armour is now becoming a standard item of equipment for police officers in the United Kingdom. In the UK these are usually required to have a stab resistance as specified by the Police Scientific Development Branch KR42 standard [G. Parker, PSDB Stab Resistant Body Armour Test Procedure, Police Scientific Development Branch, Publication No 10/93, 1993]. There are several other test standards, all of which specify that body armour must resist penetration by a specific blade type delivered at a specific energy level or range of levels. However, the actual range of energy levels specified varies over almost an order of magnitude and the basis for these levels is not clearly defined. This paper describes tests to determine the energy range and characteristics of stabbing actions that might be directed against stab resistant body armour by an assailant. The energy and velocity that can be achieved in stabbing actions has been determined for a number of sample populations. Volunteers were asked to stab a target using an instrumented knife that measured the axial force and acceleration during the stabbing. The maximum energy obtained in underarm stabbing actions was 64 J whilst overarm stabbing actions could produce 115 J. The loads produced on contact with the target often approached 1000 N.

Acceleration

Muscle sympathetic nerve response to vestibular stimulation by sinusoidal linear acceleration in humans.

To clarify the effects of natural otolith stimulation on muscle sympathetic nerve activity (MSNA) in humans, eight male volunteers were seated in a linear accelerator (sled) during the recording of MSNA from the tibial nerve with microneurography, and also the recording of electrocardiogram, blood pressure measured with a Finapres device and thoracic impedance during movement. Sinusoidal linear acceleration with peak values of +/-0.10, 0.15 and 0.20 Gx were applied to the sitting subjects in the anteroposterior direction. Both the total activity and the burst rate of MSNA decreased during the sinusoidal linear acceleration, whereas the average heart rate, thoracic impedance and mean arterial pressure did not change significantly. These results suggest that moderate sinusoidal linear acceleration in the anteroposterior direction may suppress MSNA in humans.

Acceleration