Analytical Considerations for the Development of Plate-Based Proteomics Platforms Using Isobaric Labeling.

Abstract

Mass spectrometer-based proteomics platforms have great potential to rapidly advance our systematic understanding of complex biological problems, enable drug discovery, decipher drug mechanisms of action, and discover novel biomarkers. As the demand for processing large sets of samples in an automatic manner is constantly increasing, the integration of automation platforms (nanoliter dispensers, liquid handlers, etc.) has become a routinary configuration paired with liquid chromatography-mass spectrometers. The functional integration of all of those instruments into a single unit is what we call a plate-based high-throughput proteomics platform (HT proteomics). The readout of the platform is the quantitative proteome data at the protein or peptide level. In this work, we developed a plate-based HT proteomics standard that we called the HT-sKO. The HT-sKO allows the evaluation of accuracy and the estimation of the relative limit of quantification when the target proteins vary up to 60-fold in abundance. The HT-sKO utilizes nonhuman recombinant proteins that can be spiked into the samples, allowing for sample acquisition and HT proteomics platform evaluation at the same time. We also showed the foundational role of a robust acquisition strategy for developing a stable HT proteomics platform and the value of using a tube-based method as an informant assay on data quality expectations for the platform. Using this new standard, we demonstrated that the intra- and inter-plate variance is around 4-6% for the protein level or around 10% for the peptide-level readout. We also showed that the HT-sKO standard is compatible with whole-proteome, phospho-proteome, and reactive cysteine profiling platforms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jose Navarrete-Perea, Shideh Mirhadi, Jiaming Li, Dylan Charles Mitchell, Shubhlakhan Dhillon, Ryan Hastings Gerkman, Smaranda Bodea, An Chi. 2025-12-03. Analytical Considerations for the Development of Plate-Based Proteomics Platforms Using Isobaric Labeling.. https://doi.org/10.1021/acs.analchem.5c04756

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multi-omic analyses of the same sample using metabolomics, lipidomics, proteomics, phosphoproteomics, and glycoproteomics.

Mass spectrometry (MS)-based multi-omics offers powerful tools to comprehensively characterize proteins, post-translational modifications, metabolites, and lipids. However, these measurements are typically performed using separate sample preparation workflows and modality-specific liquid chromatography mass spectrometry (LC-MS) platforms, limiting integration and constraining applications to small amounts of sample materials, especially scarce clinical specimens. Here, we describe a unified nano-LC-MS framework that enables metabolomic, lipidomic, proteomic, phosphoproteomic, and glycoproteomic analyses from the same starting material using a single nano-LC-MS platform, with only the chromatographic conditions, acquisition methods, and enrichment procedures tailored to each omics. This integrated strategy reduces workflow complexity and sample consumption while improves analytical continuity across molecular layers. By enabling deep multi-omics characterization from the same sample, this platform provides a practical foundation for comprehensive analysis of precious clinical samples.

Proteomics↗

4D-DIA proteomics reveals distinct proteolytic landscapes induced by mechanical stress, Agrobacterium, and a viral capsid precursor.

Nicotiana benthamiana is a widely used platform for plant molecular farming, yet recombinant protein yields are frequently compromised by the host's innate defense mechanisms, particularly proteolytic degradation. While the general effects of Agroinfiltration are known, the distinct contributions of mechanical injury, bacterial perception, and product-specific stress remain poorly resolved. Here we utilized high-depth 4D-DIA proteomics to dissect the host response across three dimensions: physical stress (buffer infiltration), pathogen-associated stress (Agrobacterium), and product-associated stress (GFP vs. the FMDV capsid precursor P1_2A). We demonstrate that buffer infiltration is not a neutral event but an independent inducer of cell wall remodeling and oxidative stress. By filtering out these background effects, we defined a core Agrobacterium-responsive proteome characterized by a growth-defense trade-off. We also expanded the known protease repertoire of N. benthamiana to 1,505 enzymes through improved genomic annotation. We found that the expression of the FMDV capsid precursor P1_2A was associated with a distinct and more pronounced protease profile compared to soluble GFP, characterized by the upregulation of subtilases and cysteine proteases. These findings suggest that host proteolytic responses vary with the recombinant cargo, a factor worth considering when designing engineering strategies for the production of complex biopharmaceuticals in plants.

Proteomics↗

An Instrumental Optimization of a Label-Free Proteomic Method for Trace Protein Input.

Liquid chromatography-mass spectrometry (LC-MS)-based proteomics of trace-level samples, such as tens of cells or spatially resolved tissue regions, offers unique biological insights but is often constrained by the requirement for specialized, costly instrumentation. In this study, we developed a scalable workflow for the deep proteomic analysis of low- to ultralow-input samples by systematically optimizing a widely adopted Orbitrap and UHPLC platform to maximize sensitivity, precision, and throughput. This optimized workflow identified over 5600 proteins from 5 ng of peptides and 3400 proteins from 20 sorted cells, achieving a throughput of 30 analyses per day while maintaining deep proteome coverage and high quantitative reproducibility. Furthermore, by applying this method to spatially resolved proteomics, we identified over 6100 proteins from microscale regions of interest (ROIs) within a formalin-fixed, paraffin-embedded (FFPE) tissue. A data-driven normalization strategy was employed to correct for variable cellularity across tissue regions, effectively revealing intratumor heterogeneity and distinct molecular and functional signatures, including pathway activations not apparent in parallel spatial transcriptomic analysis. Ultimately, this accessible, high-performance method substantially lowers the instrumentation barrier for the deep proteomic profiling of trace-level biological samples.

Proteomics↗