PubMed HealthSearch

PubMed · 425330

The equivalent background and retinal eccentricity.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Spillmann, K Fuld. 1979. The equivalent background and retinal eccentricity.. https://doi.org/10.1016/0042-6989(79)90040-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Noise and the absolute thresholds of cone and rod vision.

Literature data on light detection by cone and rod vision at absolute threshold are analysed in order (1) to decide whether the threshold performance of dark-adapted cone vision can, like that of rod vision, be consistently explained as limited by noise from a "dark light"; (2) to obtain comparable estimates of the dark noise and dark light of (foveal) cones and (peripheral) rods. The dark noise was estimated by a maximum-likelihood procedure from frequency-of-seeing data and compared with the dark light derived from increment-threshold functions. In both cone and rod vision, the estimated dark noise coincides with Poisson fluctuations of the estimated dark light if 17% (best estimate) of lambda max-quanta incident at the cornea produce excitations. At that fraction of quanta exciting, dark lights are equivalent to 112 isomerisations per sec in each foveal cone and 0.011 isomerisations per sec in each rod. It is concluded that (1) the threshold performance of dark-adapted cone as well as rod vision can be consistently described as noise-limited, but not by postulating a multi-quantum coincidence requirement for single receptors; (2) the underlying intrinsic activity in both the cone and the rod system is light-like as regards correspondence between noise effect and background adaptation effect. One possibility is that this activity is largely composed of events identical to the single-photon response, originating in the visual pigment, in cones as well as in rods.

Dark Adaptation

Improving the diagnostic power of electroretinography by transient alteration of the ocular perfusion pressure.

In this report we present the results of a series of studies focusing on the effects of transient changes in the ocular perfusion pressure (OPP) on retinal function in normals as assessed by the flash electroretinogram (ERG). A transient increase or decrease in the OPP affected by body inversion and compression/suction ophthalmodynamometry (ODM), respectively, is shown to affect differentially the b-wave of scotopic and photopic ERG's. However, under dark-adapted conditions, the cone component of the red flash ERG b-wave exhibited a vulnerability to decreased OPP which approached that seen for the b-wave of the scotopic blue flash ERG b-wave. Similar test procedures used to investigate the functional response of the inner plexiform layer during altered OPP revealed component-specific changes in white flash scotopic oscillatory potentials (OP's). The results of these provocative tests of retinal function offer new insights into basic retinal physiology and encouraging prospects for practical clinical diagnostic procedures with enhanced sensitivity and specificity for subclinical retinal disorders.

Dark Adaptation