PubMed HealthSearch

PubMed · 42709705

Application of musculoskeletal ultrasound in postoperative rehabilitation assessment and monitoring after rotator cuff repair: A systematic review.

Abstract

BACKGROUND: The development of rehabilitation protocols after rotator cuff repair has long lacked objective benchmarks. Traditional time‑based regimens are limited by considerable inter‑individual variability and an increased risk of re‑tear. Musculoskeletal ultrasound allows dynamic assessment of tendon healing and muscle morphology, yet evidence for directly linking its use to rehabilitation decisions remains scarce. OBJECTIVE: To systematically synthesize the evidence on the use of musculoskeletal ultrasound monitoring to inform rehabilitation decision‑making after rotator cuff repair. METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta‑Analyses (PRISMA) guidelines, we searched PubMed, China National Knowledge Infrastructure (CNKI), and Wanfang Data from January 2020 to April 2026. Original studies were included if they involved patients who had undergone rotator cuff repair, used musculoskeletal ultrasound (including gray‑scale ultrasound, elastography, etc.) to evaluate the rotator cuff tendons or shoulder muscles, and reported at least one parameter related to rehabilitation decision-making or functional outcomes. RESULTS: Eleven studies were included. Shear wave velocity (SWV), cross‑sectional area (CSA), and echo intensity (EI) were the most frequently reported ultrasound parameters. Available evidence indicated that SWV increased progressively after surgery, with an overall increase of approximately 22% to 25% from one week to 12 months postoperatively. This dynamic trajectory may serve as a reference baseline for judging rehabilitation progress. An abnormally elevated SWV in the early postoperative period was associated with an increased risk of re‑tear, suggesting that a more conservative rehabilitation strategy should be adopted. Tendon stiffness measured at 12 weeks after surgery independently predicted long‑term return to sport. Regarding muscle parameters, changes in CSA and EI were positively correlated with shoulder function scores, and the combination of these two parameters effectively identified patients with rehabilitation bottlenecks. CONCLUSION: Musculoskeletal ultrasound parameters are associated with the initiation of active movement, adjustment of exercise load, prediction of return‑to‑sport prognosis, and identification of retear risk. Among these, SWV shows particular promise as an objective monitoring parameter for supporting rehabilitation assessment after rotator cuff repair. Future randomized controlled trials are needed to determine whether ultrasound-informed assessment can improve rehabilitation outcomes compared with traditional time-based regimens, and to establish standardized measurement protocols and clinically applicable reference values. Key findings of this review are summarized in S1 File.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ying Shi, Yi Bao, Chuanxiong Li. 2026-09-08. Application of musculoskeletal ultrasound in postoperative rehabilitation assessment and monitoring after rotator cuff repair: A systematic review.. https://doi.org/10.1371/journal.pone.0357622

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Global Genomic Surveillance.

Global genomic surveillance has emerged as a foundational pillar of public health in the twenty-first century, enabling real-time tracking of pathogen evolution and informing outbreak response. This chapter examines the strategic architecture of global genomic surveillance, focusing on its application to arboviruses such as chikungunya virus (CHIKV). It explores the integration of genomic data with epidemiological, clinical, and environmental information within a One Health framework, while addressing critical challenges in governance, equity, and interoperability. The discussion covers the entire genomic surveillance workflow, from sample collection and sequencing to bioinformatic analysis and phylogenetic inference, and highlights the transformative role of artificial intelligence (AI) in predictive surveillance. By analyzing global initiatives, operational barriers, and emerging technologies, this chapter underscores the necessity of sustainable, equitable, and interoperable genomic systems to proactively address current and future infectious disease threats.

Humans

Systematic Dissection of Key Driver Perturbation Signatures in Single Cells via ECCITE-seq.

CRISPR screens, such as expanded CRISPR-compatible cellular indexing of transcriptomes and epitopes by sequencing (ECCITE-seq), enable the simultaneous measurement of transcriptomes, gRNA identity, and cell-surface protein expression at single-cell resolution to systematically interrogate gene function. This platform provides a powerful and scalable experimental approach for validating disease-associated regulators identified by large-scale association studies and other computational methods, including network-based analyses of multi-omics data. Here, as an example application, we describe an ECCITE-seq framework to characterize the transcriptomic consequences of perturbing multiple neuronal key driver genes associated with Alzheimer's disease (AD) in human-induced pluripotent stem cell (hiPSC)-derived neurons. More broadly, by integrating customized pooled gRNA libraries with different CRISPR effectors across multiple cell types, this approach allows for the assessment of the regulatory impact of candidate genes implicated in development and disease processes.

Humans

Identification of Genome-Wide Chromatin Structural Aberration in Cancer by Hi-C Analysis.

Aberrant three-dimensional genome organization is a hallmark of cancer, often driving oncogene activation through mechanisms such as enhancer hijacking. High-throughput chromosome conformation capture (Hi-C) maps these interactions on a genome-wide scale. Unlike earlier dilution-based methods, in situ Hi-C performs proximity ligation within intact nuclei, minimizing random ligation noise and enabling fine-scale structure detection. This chapter describes an optimized in situ Hi-C protocol tailored for cancer cell lines using MboI digestion and biotin-mediated pull-down to generate high-complexity libraries. We further outline a computational workflow that extends beyond standard topological mapping of compartments and topologically associating domains to identify cancer-specific aberrations. Specifically, we focus on detecting chromosomal rearrangements (structural variants) and characterizing the distinct circular topology of extrachromosomal DNA. This integrated experimental and analytical framework provides the necessary tools to dissect the spatial dysregulation underlying tumor evolution.

Humans