PubMed HealthSearch

PubMed · 43356

Purification and partial characterization of hyaluronate lyase (EC 4.2.2.1) from Propionibacterium acnes.

Abstract

Hyaluronidase from Propionibacterium acnes has been purified 13,000-fold from the culture supernatant to homogeneity (as determined by polyacrylamide disc gel electrophoresis). The molecular weight of the purified enzyme was 85,110 as determined by gel filtration. The purified enzyme had a pH optimum at 6.4, was stable between pH 5 and 5.8 and was completely inactivated after 15 min at 50 degrees C. Preliminary studies suggested that the enzyme is active against chondroitin 4- and 6-sulphates, but not against dermatan sulphate. Analysis by paper chromatography of the reaction products from the degradation of hyaluronic acid by bacterial, testicular and P. acnes enzymes suggested that the P. acnes enzyme is similar in its mode of action to other bacterial hyaluronate lyases. The enzyme from P. acnes may thus be tentatively classified as a hyaluronate lyase.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Ingham, K T Holland, G Gowland, W J Cunliffe. 1979. Purification and partial characterization of hyaluronate lyase (EC 4.2.2.1) from Propionibacterium acnes.. https://doi.org/10.1099/00221287-115-2-411

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The relative merits of polyethyleneglycol as a separating agent in the radioimmunoassay of thyroid hormones.

Polyethyleneglycol (PEG) has been recommended as a separating agent in the assay of some peptide hormones (Desbuquois, B. and Aurbach, G.D. (1971) J. Clin. Endocrinol. 33, 732) and several substances of low molecular weight (Ratcliffe, J.G. (1974) Br. Med. Bull. 30, 32). In the present study the PEG-separation technique has been modified and adapted for the assay of thyroid hormones. Separation with PEG has the advantage of being cheap, rapid and relatively non-susceptible to disturbances as compared with the charcoal and double-antibody-solid phase techniques. The influence of different buffer systems, varying pH and ionic strength, on the precipitation process with PEG also has been investigated. Of the different systems tested barbital buffer containing 0.1% human serum albumin proved to be the best, preferably in the presence of bovine gamma-globulin. In the radioimmunoassay of T3 variations in pH and ionic strength are of minor importance whereas in the radioimmunoassay of T4 the adherence to a certain pH is recommended. Barbital buffer containing 0.1% bovine serum albumin was inadequate in the T3 radioimmunoassay, while Tris and phosphate buffers did not give satisfying results for either radioimmunoassay.

Buffers