PubMed Health⌕ Search

PubMed · 438978

Stability-indicating assay for vidarabine.

Abstract

A physicochemical procedure for the analysis of vidarabine in aqueous parenteral formulations was needed to assure potency and to define stability. Concurrent with the development of this method, its decomposition products and route in aqueous solution were determined. A quantitative procedure was developed to determine intact drug in the presence of decomposition products, and the results obtained were validated by microbial assay. Spectral (UV and polarimetric) and TLC evidence indicated that, in aqueous solution, hydrolysis without racemization occurs, yielding adenine and arabinose. The sensitivity of the method to decomposition is improved by ion-exchange separation of adenine and drug before UV measurement. Analysis of partially decomposed solutions of the drug by both ion-exchange and microbiological methods gave comparable results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W H Hong, D H Szulczewski. 1979. Stability-indicating assay for vidarabine.. https://doi.org/10.1002/jps.2600680429

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Monolithic porous polymer layer for the separation of peptides and proteins using thin-layer chromatography coupled with MALDI-TOF-MS.

Plates for thin-layer chromatography (TLC) with an attached layer of porous polymer monolith have been prepared and used for the separation of small molecules, peptides, and proteins. The 50-200-mum. thin poly(butyl methacrylate-co-ethylene dimethacrylate) layers were prepared in situ using UV-initiated polymerization. Precise control of the reaction conditions enables the preparation of monolithic layers with a well-defined porous structure that determines the chromatographic performance. Compared to conventional TLC and high-performance TLC using precoated layers based on silica, the small layer thickness and absence of any binder is expected to improve both retention characteristics and separation efficiency of the polymer-based monolithic thin-layer chromatographic plates. Spots of the separated compounds were first detected using typical UV imaging. Since the monolithic thin layers can be also prepared directly on the stainless steel MALDI carrier plate, the separation in TLC format can be coupled with MALDI-TOF-MS. Application of a conventional MALDI matrix facilitated desorption and ionization of peptides and proteins for molecular weight determination of the separated compounds.

Chromatography, Thin Layer↗

Separation of solanesol in tobacco leaves extract by slow rotary counter-current chromatography using a novel non-aqueous two-phase solvent system.

Non-aqueous solvent system composed of sunflower oil-ethanol was found to be suitable for the separation of lower polarity components. Employing this solvent system, 3 g of tobacco leaves extract containing 15% solanesol was separated using a slow rotary counter-current chromatograph equipped with an 1100 mL column made of 5.7 mm I.D. convoluted PTFE tube. The separation yielded 1.5 g of yellow oily product in which solanesol occupied 26.8% determined by HPLC. The tobacco tar and other main impurities in the tobacco leaves extract were removed after slow rotary counter-current chromatographic separation. The separation processing may be developed as a technique for producing a solanesol product with food grade.

Chromatography, Thin Layer↗

Selective thin-layer chromatography of 4-R-1,2,4-triazoles.

A convenient and selective TLC of 4-R-1,2,4-triazoles (Rtrz) and nitrogen containing aromatic rings is presented (molecules 1-11). This simple revelation method implies a complexation of heterocycles to Co(II) ions on a TLC plate, followed by a subsequent modification of the reduction potential which enables oxidation of Co(II) by permanganate.

Chromatography, Thin Layer↗