PubMed HealthSearch

PubMed · 4414930

Optical diffraction analysis of petrographic thin sections.

Abstract

Diffraction patterns that are highly reproducible, of useful quality, and consistent with the input generating them can be easily obtained with a microscope system. The input can be either a reduced photograph or a thin section. With two exceptions, the relationships between a thin section and its diffraction pattern produced by a petrographic microscope are the same as the relationships between a photographic input and its diffraction pattern produced by a conventional ODA system. The exceptions are that the diffraction patterns generated directly by the thin sections may be asymmetrical or, if the thin section is sufficiently heterogeneous, may be smeared. The microscope system is generally more useful than a conventional ODA system for the analysis of microfabric in thin sections. One can readily use the microscope system to analyze elements of widely varying spatial frequency simply by changing the objectives. The diffraction patterns can be magnified by changing to a higherpower ocular. In most cases the microscope-generated diffraction pattern transmits the useful spatial information in the thin section more completely than the conventionally produced diffraction pattern; the photographic inputs for the conventionally produced diffraction pattern emphasize lower-frequency spatial information. This property, combined with the microscope system's better response to twinning, makes the microscope more sensitive to commonly used microfabric elements. For the analysis of thin sections, a conventional ODA system is superior to the microscope system in only three cases. First, if one wants to analyze the entire thin section at one time, a conventional system must be used with a photographic input of the thin section. Second, if the thin section is extremely heterogeneous (crystallographically or mineralogically), the microscope-generated diffraction pattern may exhibit gross smearing even with the highestpower objectives available. Finally, the thin section may contain only elements of low spatial frequency that will not generate diffraction dots far enough radially from the central spot to be resolvable. More study will be needed to establish the precision of spatial frequency measurements from diffraction patterns generated directly by thin sections with the microscope system. Experiments with a variety of film types and sources of illumination will, in all likelihood, lead to a reduction in the exposure times used to record diffraction patterns with the microscope (9). A complete ODA system must have directional and frequency-filtering capabilities. In order to establish these capabilities for the microscope system, components will need to be designed and fabricated and the microscope body may have to be modified. The possibility of applying the microscope technique in reflected light on a real-time basis should be investigated. This would be a valuable tool in the quantitative analysis of microfracture initiation and propagation and the analysis of overall fabric changes during experimental deformation of rock both in situ and in the laboratory. The technique presented here can be used with a less expensive microscope, if it has a focusable Bertrand lens. Our experiments with relatively inexpensive microscopes indicated that the only major problem is alignment of the illuminating system (light-filter-condenser).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P C Power, H J Pincus. 1974-10-18. Optical diffraction analysis of petrographic thin sections.. https://doi.org/10.1126/science.186.4160.234

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional motional stabilization in the trapping field of an open-ended trapped-ion cell: application to the remeasurement experiment in Fourier transform ion cyclotron resonance mass spectrometry.

Three-dimensional motional stabilization of radial trajectories of low-mass organic ions in an open cell using only a dc trapping field is applied to the FT-ICR remeasurement experiment. More than 300 remeasurement cycles are observed with 99.59% remeasurement efficiency for benzene (m/z 78) using a high-pressure helium buffer gas. The enhancement in remeasurement efficiency is due to collisional stabilization of the guiding center of ion motion by dynamic motional averaging in the axial position-dependent radial electric field. Such dc-induced radial stabilization is in contrast to the stability produced by application of radio frequency fields characteristic of quadrupolar axialization or rf-only mode operation. The same effect is produced because ions experience a radial "pseudopotential" during axial oscillation as in time-varying fields. Trajectory simulations for ions oscillating in an open cell trapping well above a z-amplitude critical threshold energy of 0.60 eV (in a potential well of 0.84 V) indicate that radially stabilized trapping motion is achieved because the outward-directed radial electric field existing near the cell center line is compensated by an opposing inward-directed radial electric field at extended z-amplitude. Sufficient axial kinetic energy permits ion penetration into the inward-directed radial electric field regions, enabling > 50% residence time of each trapping oscillation period in regions inducing radial stability, thereby inhibiting magnetron radius growth. A high-pressure, low-mass buffer gas such as helium provides the requisite increase in the axial amplitude of the ion cloud, similar to the mechanism observed for axial excitation of low-mass ions observed in collision-induced dissociation. The result is radial stability at high pressure, even after multiple remeasurement cycles. An optimized excitation radius of 12.5% of the cell radius yields maximum remeasurement efficiency with a 500 ms relaxation delay between excitation events. Summed signal intensity decreases with increased trap potential due to the greater radial electric field and reduced axial expansion of the ion cloud and also decreases with buffer gas mass in response to greater radial scattering.

Fourier Analysis

Multiple breathhold 3D time-of-flight MR angiography of the renal arteries.

A technique is described for angiographic imaging of the renal arteries with acquisition performed over several periods of suspended respiration. The 3D Fourier transform (FT) gradient-echo angiographic sequence uses magnetization preparation and appropriately chosen delay times for background nulling and time-of-flight enhancement of the vasculature. The sequence was applied to 10 volunteers, each of whom was imaged in three ways: (i) over a series of breathholds in which feedback was provided to enable reproducible breathholding; (ii) over a series of breathholds with no feedback; and (iii) over continuous respiration. Results were evaluated by measuring the transverse extent of the well-delineated renal vasculature and by noting the distal extent of the vasculature branching (main, segmental, and interlobar branches). The transverse extent of renal vasculature visible with breathhold feedback, breathholding, and free breathing was 6.1 +/- 0.9 cm, 5.0 +/- 1.8 cm, and 4.0 +/- 1.4 cm, respectively (mean +/- SD). Breathhold feedback enabled visualization of segmental renal arteries bilaterally in all 10 volunteers.

Fourier Analysis

Unexpected dominance of high frequencies in chaotic nonlinear population models.

Because water has a higher heat capacity than air, large bodies of water fluctuate in temperature more slowly than does the atmosphere. Marine temperature time series are 'redder' than atmospheric temperature time series by analogy to light: in red light, low-frequency variability has greater amplitude than high-frequency variability, whereas in white light all frequencies have the same amplitude. Differences in the relative importance of high-and low-frequency variability in different habitats affect the population dynamics of individual species and the structure of ecological communities. Population dynamics of individual species are thought to be dominated by low-frequency fluctuations, that is, to display reddened fluctuations. Here I report, however, that in eight nonlinear, iterative, deterministic, autonomous, discrete-time population models, some of which have been used to model real biological populations, the power spectral densities of chaotic trajectories are neither white nor reddened but are notably blue, with increasing power at higher frequencies.

Fourier Analysis