Intra-aortic balloon pumping: two-year experience.

Abstract

Experience with 29 patients who underwent intra-aortic counterpulsation between January, 1975, and December, 1977, was reviewed to determine (1) if the results of this method of treatment were similar at the community hospital and university hospital levels and (2) if earlier institution of counterpulsation made possible by easy availability of equipment resulted in improved survival. The balloon was successfully inserted in 27 patients. Arterial blood pressure was below 80 mm. Hg in all patients prior to institution of either pharmacologic or balloon therapy. Pulmonary capillary wedge pressure was greater than 12 mm. Hg in the 22 patients in whom it was measured. In 15 patients counterpulsation was instituted less than 12 hours after infarction (Group A), and in the 14 elapsed time was greater than 12 hours (Group B). There was no difference in precounterpulsation hemodynamic measurements between Group A and Group B. Ten patients in Group A were weaned and survived hospitalization. Seven (54 percent) are long-term survivors (6 months to 2 years). Four are in New York Heart Association Class I, two are in Class II, and one is in Class III. Ten patients in Group B were weaned, seven survived hospitalization, and five are long-term survivors (35 percent). Two are in N.Y.H.A. Class I, two are in Class II, and one is in Class III. These results indicate that counterpulsation is possible at the local hospital level and that early institution of the intra-aortic balloon pumping may improve long-term results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G L Hines, T B Delaney, M Goodman, M Mohtashemi. 1979. Intra-aortic balloon pumping: two-year experience.. https://pubmed.ncbi.nlm.nih.gov/449380/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Percutaneous endocardial and epicardial ablation of hypotensive ventricular tachycardia with percutaneous left ventricular assist in the electrophysiology laboratory.

Ventricular tachycardia (VT) in the setting of structural heart disease is challenging to treat with percutaneous catheter ablation due to the presence of complex substrate, multiple morphologies, hemodynamic instability, and epicardial circuits. When substrate-based approaches fail, however, it may be impossible to map and ablate hemodynamically unstable arrhythmias. We describe a novel approach to endocardial and epicardial mapping and ablation of hypotensive VT using a percutaneous left ventricular assist device in the electrophysiology laboratory, permitting near-surgical access to cardiac structures.

Assisted Circulation↗

IgG classification of anti-PF4/heparin antibodies to identify patients with heparin-induced thrombocytopenia during mechanical circulatory support.

Commercial immunoassays frequently detect anti-PF4/heparin antibodies during mechanical circulatory support (MCS), but only a small minority of patients develops heparin-induced thrombocytopenia (HIT). Whereas platelet functional tests can distinguish between platelet-activating and non-platelet-activating antibodies, commercial PF4-dependent immunoassays do not. Between 2003 and 2004, 113 patients were placed on MCS. Blood samples were obtained on postimplant day 5-7 for analyses by antibody assays and the functional heparin-induced platelet activation (HIPA) assay. Three distinct groups of patient sera were identified: platelet-activating anti-PF4/heparin antibodies (n = 10), non-platelet-activating anti-PF4/heparin antibodies (n = 53), and anti-PF4/heparin antibody negative (n = 50). Patients with platelet-activating antibodies had the highest risk for thromboembolic events (P < 0.005), whereas those with non-platelet-activating antibodies did not differ from antibody negative patients (P = 0.369). The enzyme-immunoassay and column agglutination assays, which cover all immunoglobulin classes, demonstrated adequate sensitivity and negative predictive value; yet, both lacked specificity with respect to the platelet-activating antibodies. If all antibody positive patients were further classified by an IgG-specific anti-PF4/heparin enzyme-immuno assay, specificity for platelet-activating antibodies increased. Whereas IgG-specific optical density (OD) values below 1.0 were likely for non-platelet-activating anti-PF4/heparin antibodies, higher values were progressively predictive for pathogenic platelet activation. The probability of the development of clinical HIT also increased steeply. In conclusion, platelet-activating anti-PF4/heparin antibodies are relatively common (about 9%) in patients on MCS and are associated with significantly higher thrombotic event rates. Low IgG-specific OD values (< 1.0) in the enzyme-immunoassay indicate low likelihood for the presence of platelet-activating antibodies. These results justify further validation so that anticoagulation during MCS becomes safer and adequate.

Assisted Circulation↗