Abstract

In this review the present state of cardiac valve replacement is summarized on the basis of the literature and personal experience in approximately 1500 cases, using various prosthetic models. Durability, hemodynamic performance at rest and during exercise, and thromboembolic risk are considered in particular and our choice of the various valve models is discussed on these grounds. The long-term durability has been significantly improved and has possibly been solved in the more advanced mechanical valves, while this question is still open in the present biological prostheses. Hemodynamic performance is considered less than optimal in all conventional mechanical prostheses and in the xenografts. Pressure gradients are abnormal in all mechanical as well as in stented biological prostheses, the latter being less likely to solve the problem of a narrow aortic root. The significantly lower incidence of thromboembolism and total valve thrombosis and the absence of anticoagulation accidents in patients with bioprostheses has tipped the balance for the present in favor of the latter, particularly in mitral valve replacement and certainly in all those patients in whom anticoagulation in impossible, unlikely, or undesirable.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H G Borst, N Papagiannakis, C Bedderman, H Oelert. 1979. Cardiac valve replacement. Problems solved and unsolved.. https://doi.org/10.1055/s-0028-1096223

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transcatheter umbrella closure of valvular and paravalvular leaks.

OBJECTIVES: Our aim was to adapt the technique of transcatheter umbrella closure of intracardiac defects for closure of valvular and paravalvular defects. BACKGROUND: The double-umbrella device developed by Rashkind and Cuaso has been safely and effectively delivered across a host of intracardiac defects, but transcatheter closure of valvular and paravalvular leaks has not been reported. METHODS: Between February 1987 and September 1990, eight patients who were believed to be poor operative candidates were taken to the catheterization laboratory for transcatheter double-umbrella closure of a valvular or a paravalvular leak. Four patients had a paravalvular leak around a prosthetic aortic valve. The other four patients had a valvular leak: one patient with a regurgitant native aortic valve after a Stansel procedure and three patients with a regurgitant porcine valve in a left ventricular apex to descending aorta conduit. RESULTS: Placement of a double-umbrella device was attempted in seven of the eight patients and was successful in all seven. Device placement was not attempted in one patient because of the crescentic shape of his defect. Two patients required two devices for each closure; the other five required only one device each. Angiography, performed on six patients after device closure, demonstrated that three patients had a completely occluded defect, two had trivial residual flow and one patient had mild residual flow through the device. All significant complications occurred in one patient who had hemolysis and oliguria that resolved when the initial umbrella was replaced by a larger device. In addition, two devices migrated to the patient's pulmonary arteries but were retrieved in the catheterization laboratory without difficulty. No other early or late complications occurred in 21 to 50 months of follow-up. Of the four patients with a paravalvular leak, the one who did not receive a device died at operation, one patient died at operation for an associated defect (in the operating room the umbrella was found securely in place across the paraaortic defect) and two patients are clinically well at home after 21 and 32 months, respectively. Of the four patients with closure of a valvular leak, one patient remains well at home 50 months later, one patient died at operation for associated defects and two patients had additional successful surgical treatment and remain well 29 months after device placement. CONCLUSIONS: Transcatheter umbrella closure appears to be a reasonable alternative for closure of a valvular or paravalvular leak in patients who are poor operative candidates.

Aortic Valve

[Results of heart valve replacement. Prognosis--occupational and general disability--occupational rehabilitation].

The success of valve surgery has led to a marked improvement in prognosis, quality of life and exercise tolerance in patients with symptomatic valvular heart disease. The degree of subjective and objective improvement depends on multiple preoperative factors like NYHA status, left ventricular function, valve lesion and type of valve replaced as well as peri- and postoperative factors like the occurrence of a perioperative myocardial infarction, the degree of intraoperative myocardial damage, the type of valve replaced and the speed and degree of postoperative regression of left ventricular hypertrophy and dilatation. The postoperative exercise tolerance is a major determinant for postoperative vocational rehabilitation. Therefore the individual functional assessment of patients postoperatively is of major importance.

Aortic Valve