PubMed Health⌕ Search

PubMed · 4557293

[The foil prosthesis--a help in deep bite?].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H J Rehberg. 1972. [The foil prosthesis--a help in deep bite?].. https://pubmed.ncbi.nlm.nih.gov/4557293/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Improvement in the mucoadhesive properties of alginate by the covalent attachment of cysteine.

The purpose of the present study was to improve the mucoadhesive properties of alginate by the covalent attachment of cysteine. Mediated by a carbodiimide, L-cysteine was covalently linked to the polymer. The resulting thiolated alginate displayed 340.4+/-74.9 micromol thiol groups per g conjugate (means+/-S.D.; n=4). Within 2 h the viscosity of an aqueous mucus/alginate-cysteine conjugate mixture pH 7.0 increased at 37 degrees C by more than 50% compared to a mucus/alginate mixture, indicating enlarged interactions between the mucus and the thiolated polymer. Tensile studies carried out on freshly excised porcine intestinal mucosa demonstrated a total work of adhesion (TWA) of 25.8+/-0.6 and 101.6+/-36.1 microJ for alginate and the alginate-cysteine conjugate, respectively (means+/-S.D.; n=5). The maximum detachment force (MDF) was thereby in good correlation with the TWA. Due to the immobilization of cysteine, the swelling velocity of the polymer was significantly accelerated (P<0.05). In aqueous media the alginate-cysteine conjugate was capable of forming inter- and/or intramolecular disulfide bonds. Because of this crosslinking process within the polymeric network, the cohesive properties of the conjugate were also improved. Tablets comprising the unmodified polymer disintegrated within 49+/-14.5 min, whereas tablets of thiolated alginate remained stable for 148.8+/-39.1 min (means+/-S.D.; n=3). These features should render thiolated alginate useful as excipient for various drug delivery systems providing an improved stability and a prolonged residence time on certain mucosal epithelia.

Adhesiveness↗

Effects of an adhesion promoter on the debond resistance of a metal-polymethylmethacrylate interface.

Debonding and premature failure of prostheticpolymethylmethacrylate interfaces have been shown to be exacerbated by exposure to physiological environment. In efforts to counteract these hydrolytic degradation effects, two clinically relevant Co-Cr-Mo surface morphologies were treated with an organosilane adhesion promoter (gamma-methacyloxypropyltrimethoxy) before interface bonding. Samples were quantitatively characterized in terms of the adhesion (fracture) and subcritical debond growth-rate (fatigue) behavior of the interface. The steady-state interface debond resistance, Gss (J/m2), was shown to increase with application of the silane pretreatment both in air (20 degrees C, 45% relative humidity) and simulated physiological environment (37 degrees C, Ringer's). Similarly, positive shifts in the subcritical debond threshold, deltaG(TH), values are observed for silane pretreated interfaces. A shift in the debond path from primarily adhesive failure in untreated surfaces to cohesive failure between the silane layer and bulk polymethylmethacrylate for silane treated surfaces was observed. Silane pretreatment of Co-Cr-Mo surfaces was shown to effectively limit the degree of the environmental degradation. General insights to the effects of surface roughness, chemical enhancement, and the environmental effects on the thermodynamics at the interface and resulting debond behavior are discussed.

Adhesiveness↗

A microcantilever device to assess the effect of force on the lifetime of selectin-carbohydrate bonds.

A microcantilever technique was used to apply force to receptor-ligand molecules involved in leukocyte rolling on blood vessel walls. E-selectin was adsorbed onto 3-microm-diameter, 4-mm-long glass fibers, and the selectin ligand, sialyl Lewis(x), was coupled to latex microspheres. After binding, the microsphere and bound fiber were retracted using a computerized loading protocol that combines hydrodynamic and Hookean forces on the fiber to produce a range of force loading rates (force/time), r(f). From the distribution of forces at failure, the average force was determined and plotted as a function of ln r(f). The slope and intercept of the plot yield the unstressed reverse reaction rate, k(r)(o), and a parameter that describes the force dependence of reverse reaction rates, r(o). The ligand was titrated so adhesion occurred in approximately 30% of tests, implying that >80% of adhesive events involve single bonds. Monte Carlo simulations show that this level of multiple bonding has little effect on parameter estimation. The estimates are r(o) = 0.048 and 0.016 nm and k(r)(o) = 0.72 and 2.2 s(-1) for loading rates in the ranges 200-1000 and 1000-5000 pN s(-1), respectively. Levenberg-Marquardt fitting across all values of r(f) gives r(o) = 0.034 nm and k(r)(o) = 0.82 s(-1). The values of these parameters are in the range required for rolling, as suggested by adhesive dynamics simulations.

Adhesiveness↗