PubMed Health⌕ Search

PubMed · 4566372

A simple device for red cell saponization.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Inwood. A simple device for red cell saponization.. https://pubmed.ncbi.nlm.nih.gov/4566372/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The influence of detergents and amphiphiles on the solubility of the light-harvesting I complex.

The effect of detergents and amphiphiles on protein solubility and their use in crystallization solutions was examined for an integral membrane protein, the light-harvesting I complex from Rhodospirillum centenum. Measurement by a centrifugation assay of the solubility of the protein in different detergents and amphiphiles showed high protein-solubility values when either octyl glucoside or lauryldimethylamine-N-oxide was present with heptanetriol or when deoxycholate was present with spermine. The detergent/amphiphile combinations that resulted in high protein solubility were shown to be successful for crystallization of the protein, suggesting that crystallization is favored for detergents and amphiphiles that optimize the solubility of integral membrane proteins. The amphiphiles effective for crystallization were found using laser mass spectrometry to displace the lauryldimethylamine-N-oxide bound to the protein. These results suggest that mass spectrometry can be used for screening of favorable crystallization conditions.

Centrifugation↗

Rational improvement of centrifugal partition chromatographic settings for the production of 5-n-alkylresorcinols from wheat bran lipid extract. I. Flooding conditions--optimizing the injection step.

A dedicated CPC prototype permits direct flow pattern visualization in the partition cells of a CPC column. It was used to understand "flooding", a frequent phenomenon associated with large injections. A general strategy was developed to optimize the injection step in the framework of a particular preparative separation: the purification of 5-n-alkylresorcinols from a wheat bran lipid extract on a several hundred milligram scale. The construction of the "mobile phase/stationary phase/sample" pseudo ternary diagram characterizes the effect of the injected solution on mobile and stationary phases. The position of the binodal curve maximum indicates if the biphasic system is "robust" towards a large injection or not, and can be used for optimum mass load determination.

Centrifugation↗

Protein separation by nonsynchronous coil planet centrifuge with aqueous-aqueous polymer phase systems.

Counter-current chromatographic separation of proteins was performed using a rotary-seal-free nonsynchronous coil planet centrifuge (CPC) fabricated in our laboratory. This apparatus has a unique feature that allows a freely adjustable rotational rate of the coiled separation column at a given revolution speed. The separation was performed using a set of stable proteins including cytochrome c, myoglobin and lysozyme with two different types of aqueous-aqueous polymer phase systems, i.e., PEG (polyethylene glycol) 1000-dibasic potassium phosphate, and PEG 8000-dextran T500 in 5 mM potassium phosphate buffer. Using a set of multilayer coiled columns prepared from 0.8 mm I.D. PTFE tubing with different volumes (11, 24, 39 ml), the effect of the column capacity on the partition efficiency was investigated under a given set of experimental conditions. Among these experiments, the best separation of proteins was attained using the 39 ml capacity column with a 12.5% (w/w) PEG 1000-12.5% (w/w) dibasic potassium phosphate system at 10 rpm of coil rotation under 800 rpm. With lower phase mobile at 0.2 ml/min in the head-to-tail elution, the resolution between cytochrome c and myoglobin was 1.6 and that between myoglobin and lysozyme, 1.9. With upper phase mobile in the head-to-tail elution, the resolution between lysozyme and myoglobin peaks was 1.5. In these two separations, the stationary phase retention was 35.0 and 33.3%, respectively. Further studies were carried out using a pair of eccentric coil assemblies with 0.8 mm I.D. PTFE tubing at a total capacity of 20 ml. A comparable resolution was obtained using both lower and upper phases as a mobile phase in a head-to-tail elution. The results of our studies demonstrate that the nonsynchronous CPC is useful for protein separation with aqueous-aqueous polymer phase systems.

Centrifugation↗