PubMed HealthSearch

PubMed · 4649635

[Iodine].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Bergan. 1972-11-30. [Iodine].. https://pubmed.ncbi.nlm.nih.gov/4649635/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Solid-phase microextraction with temperature-programmed desorption for the analysis of iodination disinfection byproducts.

An analytical approach for the determination of chlorination and iodination disinfection byproducts based on solid-phase microextraction (SPME) was developed. Solid-phase microextraction presents a simple, rapid, sensitive, and solvent-free approach to sample preparation in which analytes in either air or water matrixes are extracted into the polymeric coating of an optical fiber. Analytes are subsequently thermally desorbed in the injection port of a gas chromatograph for separation, detection, and quantitation. Thermal degradation of iodoform was observed during desorption from a polyacrylate fiber in initial GC/MS and GC/ECD experiments. Experiments were designed to determine SPME conditions that would allow quantification without significant degradation of analytes. Isothermal and temperature-programmed thermal desorptions were evaluated for efficacy in transferring analytes with wide-ranging volatilities and thermal stabilities into chromatographic analysis columns. A temperature-programmed desorption (TPD) (120-200 degrees C at 5 degrees C/min with an on-column injection port or 150-200 degrees C at 25 degrees C/min with a split/splitless injection port) was able to efficiently remove analytes with wide-ranging volatilities without causing thermal degradation. The SPME-TPD method was linear over 2-3 orders of magnitude with an electron capture detector and detection limits were in the submicrogram per liter range. Precision and detection limits for selected trihalomethanes were comparable to those of EPA method 551. Extraction efficiencies were not affected by the presence of 10 mg/L soap, 15 mg/L sodium iodide, and 6000 mg/L sodium thiosulfate. The SPME-TPD technique was applied to the determination of iodination disinfection byproducts from individual precursor compounds using GC/MS and to the quantitation of iodoform at trace levels in a water recycle system using GC/ECD.

Disinfectants

Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid.

OBJECTIVE: This study was undertaken to evaluate the efficacy of 4 new low-temperature sterilization technologies: ethylene oxide with hydrochlorofluorocarbons, a liquid peracetic acid immersion system (Steris System 1 Processor), and 2 plasma sterilization processes that use vaporized hydrogen peroxide (Sterrad 100 and the Sterrad 100S). The Sterrad 100S system potentially improves sterilizer efficacy by using 2 cycles of a diffusion stage and a plasma stage per sterilization cycle. METHODS: Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were aseptically placed in the middle of 40 cm long stainless steel lumens (hollow tubes). Two types of lumen were used:(1) a lumen test unit with a removable 5 cm center piece (1.2 cm diameter) of stainless steel sealed to the narrower steel tubing by hard rubber septums and (2) a straight lumen. Three different diameters of the lumen test unit (1, 2, and 3 mm) and a single diameter of the straight lumen (3 mm) were studied. At least 40 replicates were performed for each type of lumen and sterilization method. After inoculation, the test unit was evaluated in 1 of the low-temperature sterilization technologies. After sterilization, the carriers were cultured in trypticase soy broth for 14 days at 55 degrees C and assessed for growth of B stearothermophilus spores. RESULTS: Our results demonstrated that ethylene oxide with hydrochlorofluorocarbons, the Sterrad 100s, and the Sterrad 100S half cycle were highly effective in killing approximately 10(6) B stearothermophilus spores present in the center of narrow-lumen stainless steel tubes. As the lumen diameter decreased with the lumen test unit, the Sterrad 100 demonstrated reduced ability to kill B stearothermophilus spores present on the carrier. At the smallest diameter tested (1 mm), the Sterrad 100 system failed 74% of the time. The Steris System 1 was not effective in completely eliminating the 10(6) inoculum under test conditions. CONCLUSION: The Sterrad 100S was significantly superior to the Sterrad 100 system and equivalent to ethylene oxide with hydrochlorofluorocarbons. Introduction of this new Sterrad 100S system should improve the margin of safety and reduce processing costs by its use of a shorter cycle time. The Steris System 1 is limited by diffusion of the chemical sterilant into the interior of the lumen test unit.

Disinfectants