PubMed HealthSearch

PubMed · 4664708

[Generalized eczema and an osteosynthesis screw].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Oleffe, J Wilmet. [Generalized eczema and an osteosynthesis screw].. https://pubmed.ncbi.nlm.nih.gov/4664708/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation.

STUDY DESIGN: In a prospective study of 90 patients undergoing lumbar pedicle screw instrumentation, 512 screws were tested intraoperatively using electrical stimulation. The accuracy of this technique was verified after surgery by computed tomography. OBJECTIVES: Computed tomographic scans taken after surgery were used to evaluate the efficacy of intraoperative screw stimulation and electromyographic monitoring of pedicle screw placement. SUMMARY OF BACKGROUND DATA: Previous cadaveric and clinical studies showed the risk of pedicle screw malposition and the inadequate reliability of intraoperative radiographs to identify misplaced screws. METHODS: Screws (total, 512) in 90 patients were stimulated intraoperatively, and stimulation threshold was recorded. Computed tomographic scans were taken after surgery to document pedicle screw position. Electromyographic thresholds and computed tomographic data were evaluated independently and compared to assess the accuracy of the electromyographic screw stimulation technique. RESULTS: Intraoperative screw stimulation was extremely accurate in confirming the adequacy of screw position. A stimulation threshold greater than 15 mA provided a 98% confidence that the screw was within the pedicle. In eight of 90 patients (9%), electromyographic monitoring detected a screw malposition that was not identified on lateral radiograph. CONCLUSIONS: Screw stimulation monitoring is a valuable and efficacious adjunct to lumbar pedicle screw instrumentation. A stimulation threshold greater than 15 mA reliably indicates adequate screw position. A stimulation threshold between 10 and 15 mA was generally associated with adequate screw position, although exploration of the pedicle is recommended. A stimulation threshold less than 10 mA was associated with a significant cortical perforation in most instances.

Bone Screws

Image-guided insertion of transpedicular screws. A laboratory set-up.

STUDY DESIGN: A computer-assisted system allowing precise preoperative planning and real-time intraoperative image localization of surgical instruments is tested in a laboratory setup. OBJECTIVES: The purpose of this study is to assess the applicability, functionality, and accuracy of this transpedicular spinal fixation technique. SUMMARY OF BACKGROUND DATA: Most techniques in transpedicular spinal fixation rely on the identification of predefined targets with the help of anatomic landmarks and on the intraoperative use of image intensifiers. Various studies report considerable screw misplacement rates which may lead to serious clinical sequelae such as permanent nerve damage. METHODS: The proposed system was tested in an in vitro setup drilling 20 pedicle pilot holes in lumbar vertebrae. The accuracy was assessed using precision cuts through the pedicles and simulation of a 6-mm pedicle screw insertion. RESULTS: An ideal screw position was found in 70 of 77 cuts, and in no case was an injury to the pedicular cortex observed. CONCLUSIONS: The presented technique provides a safe, accurate, and flexible basis for transpedicular screw placement in the spine. This approach should be further evaluated in clinical applications.

Bone Screws

Correction of dorsi-flexed intercalated segment instability after restoration of scaphoid height in a cadaver model of scaphoid non-union.

Models of scaphoid non-union with static dorsi-flexed intercalated segment instability were produced in five frozen arms from cadavers or subjects following accidents by repetitive mechanical loading of the wrist joints longitudinally after a bone defect has been made at the mid-portion of the scaphoid. We designed four models of reduction: anatomical reduction; reduction with a shortened scaphoid; anatomical reduction but with the radio-lunate ligament sectioned, and a shortened scaphoid with the radio-lunate ligament sectioned. Results suggested that anatomical reduction with rigid fixation with a Herbert screw was most effective for correction of malalignment with DISI. Preservation of the radio-lunate ligament during the palmar approach to the scaphoid seemed to be important to prevent ligamentous carpal instability.

Bone Screws