PubMed HealthSearch

PubMed · 4702414

Luminance-dependent changes in mesopic visual contrast sensitivity.

Abstract

Spatial and temporal modulation transfer functions have been measured as a function of luminance at scotopic and mesopic levels. It is found that throughout the scotopic range the data can be accounted for by a two process visual system, with the processes having the following properties. Simple excitatory processThis mechanism summates over somewhat less than 1 square degree of visual angle and over about 200 msec of time. These properties do not change with luminance, but the over-all sensitivity of the mechanism follows the De Vries-Rose law. The temporal properties of this mechanism follows those of the scotopic b-wave. At high luminances, the temporal, but not spatial, properties of this mechanism break down in a manner which had not been studied.Low-frequency inhibitory processThis process is manifest as a decrease in sensitivity from that of the simple excitatory process. Its effect is observed only when both spatial and temporal frequency are low, suggesting that it has a larger (perhaps 3 x) summation area in both space and time. The inhibitory process is not observed below a certain threshold luminance, which is highly dependent upon the configuration of the stimulus. For a suitable stimulus, this threshold will be well into the scotopic luminance range.It is suggested that these two processes represent psychophysical correlates of the centre and surround of retinal receptive fields.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R A Smith. 1973. Luminance-dependent changes in mesopic visual contrast sensitivity.. https://doi.org/10.1113/jphysiol.1973.sp010178

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stereopsis and positional acuity under dark adaptation.

Though experience tells us we can perceive depth in dim light, it is not so obvious that one of the chief mechanisms for depth perception, stereopsis, is possible under scotopic conditions. The only studies on human stereopsis in the dark adapted state seem to be those of Nagel [(1902) Zeitschrift für Psychologie, 27, 264-266] and Mueller and Lloyd [(1948) Proceedings of the National Academy of Science, U.S.A., 34, 223-227], both of which used real objects or line stereograms. We tested stereopsis using both random-dot and line stereograms and, in agreement with these studies, found that stereopsis is indeed possible in dark adaptation. We also measured stereo acuity and positional acuity (both of which are examples of hyperacuity) and compared these with grating acuity at several levels of light and dark adaptation. At all illumination levels tested, acuities for stereopsis and relative line position were both higher than for grating acuity. As light levels decreased, positional and grating acuity declined in parallel fashion, whereas stereoacuity declined more steeply.

Dark Adaptation

Optimised averaging by on-line statistical verification of response in clinical electrodiagnostic trials.

Real time statistical verification of the averaged response in many established electrodiagnostic tests may result in a substantially reduced number of presented stimuli thus minimising the test's duration and reducing the overall time load on the patient examined. Furthermore, a sufficient number of stimuli may be automatically established in an objective statistical way by accounting for the response amplitude and variance, noise amplitude etc., resulting in averages with matching signal to noise ratio. A technique of real time statistical verification of the response based upon single trial data analysis was developed and verified in clinical electroretinographic (ERG) tests.

Dark Adaptation