PubMed HealthSearch

PubMed · 480121

[The limulus test: introduction to the round table].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Puech. [The limulus test: introduction to the round table].. https://pubmed.ncbi.nlm.nih.gov/480121/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Endotoxin testing with limulus amoebocyte lysate in a radiopharmaceutical containing chelated metallic radionuclides and chelating agents.

The gel formation by endotoxin with limulus amoebocyte lysate (LAL) solution requires the presence of free calcium ions. The chelating agents and radiopharmaceuticals prepared from the chelating agents always reduce the available free calcium levels present in the kits used for the testing of apyrogenicity and thus inhibit gel formation of LAL with E. Coli endotoxin (ET). This inhibition of gel formation could be reversed by the addition of excess free calcium ions or the excessive dilution of radiopharmaceuticals and chelating agents. The tests of positive control (0.2 ml ET units and LAL), inhibition control (0.1 ml sample, 0.1 ml ET and LAL), and negative control (0.1 ml sterile saline and LAL) were carried out with the fresh preparation (0.1 ml) of samples (triplicate), tropolone, ACD anticoagulant, and 99mTc-labeled radiopharmaceuticals. In the Ca-supplemented tests, 0.1 ml of 60 mM sterile calcium chloride solution was added to the test solutions and incubated for 60 min at 37 degrees centigrade. The results of gel formation (+ve and -ve) and normalization of inhibition control tests with Ca-supplement indicate that commercial LAL kits need extra calcium ions for the correct testing of the apyrogenicity of chelate-containing radiopharmaceuticals and chelating agents.

Limulus Test

Studies on a simple Limulus test, a slide method.

A simple micromethod of Limulus test was studied. Briefly, this method is as follows. A 20 microliter aliquot of Pregel lysate solution and the same amount of sample are dropped on the same place on the silicone coated slide glasg and mixed well. Then it is incubated at 37 degrees C for 30 minutes in a moisture chamber. After the incubation, the vibration of the droplet surface is observed. When the vibration is no longer observed, it is judged as positive reaction, and when the vibration is still observed as before the incubation, it is judged as negative reaction. Compared with the conventional tube method, this method has advantages as below: 1) the judgement of the result is relatively objective, 2) shorter incubation period is enough for the reaction to take place and 3) smaller amount of Limulus lysate is enough for each sample. Besides these merits, the detection limit of this method is not inferior to that of the tube method.

Limulus Test

Variability in the LAL test: comparison of three kinetic methods for the testing of pharmaceutical products.

Data presented in this study indicate that there is considerable variability in spike recoveries between three different kinetic LAL methods as used for the testing of a variety of parenteral products. However, successful spike recoveries were observed for each of the thirteen products under test on at least one of the three kinetic methods used, suggesting that problems caused by spike recovery variability may be easily controlled in the laboratory by flexibility in the choice of method.

Limulus Test