Abstract

The design and implementation of a program to investigate remote quality assurance testing for film mammography is described. The measurements included tube output, x-ray machine and processor stability, and film quality. Mammography phantoms and film sensitometric strips were distributed monthly to 24 regional hospitals. Most of the hospital processors and x-ray machines performed in a stable manner during the 12-month test period. It was found that x-ray machine useful beams could be reliably measured using nonscreen films. The main utility of the phantom was to identify cases of poor image quality. The measurements performed on the phantom image could not be used to diagnose specific causes of poor images.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Burgess. 1979. A mammography quality assurance test program.. https://doi.org/10.1148/133.2.491

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A high resolution workstation prototype for diagnosis of digital mammograms.

The development of a total digital high resolution mammography display system must meet a number of requirements that remain a challenge nowadays, most probably because of the special nature of breast imaging. In this paper, we discuss our particular approach to address some problems concerning the complexity of soft-copy diagnosis in digital mammography, such as image quality and user interface evaluation. Based on the experience obtained in the previous implementation of a medical image browser, a more ambitious project is being developed at the Department of Radiology of the University of Santiago de Compostela (Spain) in collaboration with the Department of Medical Informatics of INTELSIS, an emerging software company in our country. This new system will provide complete support to display, store and analyze mammographic studies in digital format.

Mammography↗

Grid and slot scan scatter reduction in mammography: comparison by using Monte Carlo techniques.

PURPOSE: To evaluate a comprehensive array of scatter cleanup techniques in mammography by using a consistent methodology. MATERIALS AND METHODS: Monte Carlo techniques were used to evaluate the Bucky factor (BF) and the contrast improvement factor (CIF) for linear and cellular grids and for slot scan and scanning multiple-slot assembly (SMSA) systems. RESULTS: For a 28-kVp molybdenum anode-molybdenum filter spectrum with a standard detector and a 6-cm-thick 50% adipose-50% glandular breast phantom, slot scan techniques delivered an ideal BF. For slot widths greater than 4 mm, however, the CIF was lower than that achieved by the high-transmission cellular grid with a grid ratio of 3.8:1. A tungsten-septa air-interspaced cellular grid with a 4:1 grid ratio outperformed the high-transmission cellular grid in both BF and CIF. The SMSA was shown to be efficacious when 4-mm-wide slots were separated by at least 20 mm. In comparison with the literature, 3.6% agreement was achieved with other Monte Carlo studies, 3.3% with an experimental study that used a digital detector, and 13%-29% agreement was demonstrated in comparison to film-based experimental studies. CONCLUSION: With use of consistent methods for comparison, cellular grids were shown to substantially outperform linear grids but have slightly higher BFs compared with that of slot scan geometries at the same CIF.

Mammography↗