PubMed HealthSearch

PubMed · 4944296

[Data recorder for autoanalysers].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Becker, U Faust, H Keller. 1971-10-05. [Data recorder for autoanalysers].. https://doi.org/10.1515/bmte.1971.16.5.192

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrophysical factors influencing endoscopic sphincterotomy.

BACKGROUND: Analog computer techniques were used to measure electrosurgical power during sphincterotomy in experimental models and patients. METHODS: Total energy and transient changes in power were measured during sphincterotomy of bile ducts in the livers of pigs, ampullae of humans post mortem, and during clinical sphincterotomy. The effect of waveform on hemostasis was studied in experiments on canine mesenteric arteries. RESULTS: Electrosurgical waveforms (CUT, COAG, BLEND) were measured. Halving wire contact length halved energy needed to initiate cutting. The CUT waveform rarely initiated cutting at lower power settings than the BLEND waveform. With CUT, BLEND, and COAG waveforms, approximately the same energy initiated cutting. Efficiency of cutting increased linearly with power. The COAG waveform required higher power settings than BLEND or CUT to initiate cutting (p < 0.05). Force and wire diameter influenced cutting. BLEND was more effectively hemostatic than CUT (p < 0.05). COAG was significantly more hemostatic than BLEND and CUT. Cutting efficiency during clinical sphincterotomy was poor. CONCLUSIONS: This work has practical implications. Shortening wire contact length was effective in starting a cut at suboptimal settings, whereas changing from BLEND to CUT made little difference. Increasing power setting may help if cutting does not start. BLEND stops bleeding better than CUT. COAG stops bleeding better than BLEND but cuts poorly. Cutting during clinical sphincterotomy is inefficient and can be improved.

Analog-Digital Conversion

Chaotic dynamics in circulation with Tohoku University vibrating flow pump.

For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relative high frequency (10-50 Hz) for a totally implantable system. In this study, the effects of left ventricular assistance with this unique oscillated blood flow were analyzed by the use of nonlinear mathematics for evaluation as the whole circulatory regulatory system, not as the decomposed parts of the system. Left heart bypasses using the VFP from the left atrium to the descending aorta were performed in chronic animal experiments using healthy adult goats. The ECG, arterial blood pressure, VFP pump flow, and the flow of the descending aorta were recorded in the data recorder during awake conditions and analyzed in a personal computer system through an A-D convertor. By the use of nonlinear mathematics, time series data were embedded into the phase space, the Lyapunov numerical method, fractal dimension analysis, and power spectrum analysis were performed to evaluate nonlinear dynamics. During left ventricular assistance with the VFP, Mayer wave fluctuations were decreased in the power spectrum, the fractal dimension of the hemodynamics was significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that nonlinear dynamics, which mediate the cardiovascular dynamics, may be affected during left ventricular (LV) bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. Decreased sympathetic discharges may be the origin of the decreased Mayer wave and fractal dimension. These nonlinear dynamic analyses may be useful to design optimal VAS control.

Analog-Digital Conversion

Measurement of tidal volume by using transthoracic impedance variations in rats.

The application of impedance pneumography for monitoring respiration in small animals has been limited by problems with calibration. With improved instrumentation, we describe the calibration of tidal volume in anesthetized rats. The detection of changes in voltage, reflecting the electrical impedance variations associated with respiration, was optimized by using disposable adhesive silver-silver chloride electrodes, advanced circuitry, and analog-to-digital recording instrumentation. We found a linear relationship between change in impedance and tidal volume in individual rats (R2 >/= 98%), which was strongly influenced by rat weight. Consequently, a calibration equation incorporating change in impedance and rat weight was derived to predict tidal volume. Comparison of the predicted and true tidal volumes revealed a mean R2 >/= 98%, slopes of approximately 1, intercepts of approximately 0, and bias of approximately 0.07 ml. The predicted volumes were not significantly affected by either frequency of respiration or pulmonary edema. We conclude that impedance pneumography provides a valuable tool for the noninvasive measurement of tidal volume in anesthetized rats.

Analog-Digital Conversion