Reproducibility of +Gz tolerance testing.

Abstract

The +Gz tolerance of USAF aircrewmen undergoing medical evaluation has been tested at the USAF School of Aerospace Medicine since 1973. For various reasons, the test protocol can usually be carried out only once on these patients. Accurate determination of the +Gz tolerance of aircrewmen who fly high performance fighter aircraft is very important in assuring aero-medical safety, since loss of consciousness as a result of exceeding a pilot's G tolerance may result in loss of life and loss of aircraft. It is, therefore, necessary to estimate the variability associated with each profile of the test so that a more accurate assessment of +Gz tolerance can be made. Multiple repeat medical evaluation test protocols were performed on 17 centrifuge acceleration panel members. The standard deviations in the +Gz measurements for the four centrifuge profiles were GOR(1) = 0.38 Gz, ROR=0.22 Gz, GOR(2)=0.34 Gz, and GOR(S)=0.39 Gz. A statistically significant learning effect, which increases +Gz tolerance, was observed in both experienced and inexperienced subjects. Knowledge of the variability associated with each test profile will allow a more accurate definition of an individual +Gz tolerance when only a single centrifuge test protocol can be performed. In addition, possible future use of this centrifuge protocol in the selection of individuals with above- or below-average +Gz tolerance is facilitated with an accurate assessment of the variability associated with the test.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J E Whinnery, W G Jackson. 1979. Reproducibility of +Gz tolerance testing.. https://pubmed.ncbi.nlm.nih.gov/496752/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Burns in an aeronautic environment].

Following an examination of the aetiology of burns in aeronautic environments, the physiopathology, classification and general and local treatment of the burn case is discussed. Special mention is then made of aircraft as an extremely useful means of transport.

Aerospace Medicine

[Peculiar electrocardiographic findings in space medicine].

An account is given of some peculiar ECG pictures observed during two studies performed at the Air Force Aerospatial Medicine Research Centre. The first study covered in-flight heart rate recordings in trainee pilots and can be regarded as an early example of dynamic ECG, as also employed in the rehabilitation of heart patients and in sport for both diagnostic and preventive purposes. It was performed four years ago. The second study, run on subjects undergoing protracted high centrifugal acceleration, revealed: tachycardia, bradycardia, pulmonary P, repolarisation disturbances, alterations in the level of the ST segment, etc. An aetiopathogenetic assessment is made of these alterations and some personal observations are added. It is suggested that dynamic ECG could be more widely employed in experiments in this field as a powerful research tool.