PubMed HealthSearch

PubMed · 4978778

Development of human complement system.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Fireman, D A Zuchowski, P M Taylor. 1969. Development of human complement system.. https://pubmed.ncbi.nlm.nih.gov/4978778/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Flow cytometry cross-match: a method for predicting graft rejection.

Long-term graft survival is mainly influenced by early graft rejection and posttransplant graft function. The ability of both complement-dependent cytotoxicity cross-match (CDC) and flow cytometry cross-match (FCXM) to predict acute rejection episodes has been evaluated by cross-matching 40 patients who received cadaveric kidney transplants, before (current serum) and after transplantation (on days 1, 7, 14, 21, 28, 60, and 90). Of the 40 patients, all of whom had a negative CDC before transplant, seven patients had a positive FCXM before transplant: five of them (5/7=71.4%) experienced severe rejection within 2 months after transplantation. In patients with a negative FCXM before transplant, the incidence of acute rejection was lower (25.8%). Pre-transplant FCXM recipients who had a positive FCXM after transplant, experienced more frequent rejection (38.5%) than those pre-transplant FCXM recipients who never had a positive FCXM (15.8%). With respect to the incidence of acute graft rejection, no difference was found between patients who had a positive CDC after transplant and those who had a negative CDC after transplant. Patients who had a positive FCXM before transplant had significantly higher creatinine levels within the first month after transplant. Immediate onset of function and accelerated lowering of the creatinine level were found to be more frequent in patients who had a negative FCXM before transplant. As early graft rejection is the largest contributing factor for the development of chronic rejection and, therefore, of graft loss, we regard FCXM as a sensitive method for predicting long-term prognosis and graft survival, due to its competence in predicting both restricted graft function and early acute rejection, in particular.

Complement System Proteins

Complement consumption by poly(ethylene glycol) in different conformations chemically coupled to poly(isobutyl 2-cyanoacrylate) nanoparticles.

There is an increasing interest to develop injectable drug polymeric carriers not recognizable by the body as foreign particles and eliminated very quickly from the bloodstream. A polyethylene glycol (PEG)-coating onto injectable particles showed to reduce either protein adsorption and complement consumption, as a function of the PEG density. In this work we compared the complement rejecting ability of PEG in different conformations coupled to polyisobutylcyanoacrylate (PIBCA) nanoparticles, through the analysis of the residual hemolytic capacity of the human serum after contact with the particles. Nanoparticles were formed by chemical coupling of PEG during emulsion/polymerization of isobutylcyanoacrylate (IBCA). Nanoparticles characterization included an investigation of their surface properties, such as hydrophilicity and conformational mobility of the PEG chains grafted on the nanoparticles surface, and PEG total content. The polymerization kinetics of IBCA in presence of PEG or MePEG were also studied. Complement consumption was observed to be very sensitive to the number of particles in contact with human serum, as well as to the PEG conformation, suggesting PEG configuration could affect the particle exposed surface.

Complement System Proteins

The role of immunoglobulin G and fibrinogen in platelet aggregation by Streptococcus sanguis.

Previous work has shown that the type strain of Streptococcus sanguis, NCTC 7863, induces aggregation of normal platelets by a complement-dependent mechanism. We investigated the roles of IgG and fibrinogen in the aggregation process. Plasma depleted of IgG by passage through protein A-sepharose failed to support platelet aggregation, as did plasma absorbed at 0 degrees C with whole bacteria. However, absorption of plasma with a non-aggregating strain of S. sanguis, SK96, did not remove aggregating activity for NCTC 7863. Supplementing 0 degrees C-absorbed plasma with purified IgG restored the aggregation supporting activity. A monoclonal antibody to the Fc gammaRII receptor inhibited platelet aggregation by the bacteria, indicating a requirement for bacteria-IgG complexes interacting with the Fc receptor in platelet aggregation. There was a lag time to the onset of platelet aggregation of 7-19 min depending upon the platelet donor, but the length of this lag did not correlate with either total IgG concentration recognizing NCTC 7863 in subjects' plasma, or the concentration any of the four IgG subclasses or with IgG avidity levels. Fibrinogen was shown to bind rapidly to the bacterial cell surface. Monoclonal antibody to GPIIb/IIIa, RGDS peptide, and a specific antagonist for the platelet fibrinogen receptor, GPIIb/IIIa, FK633, inhibited platelet aggregation by NCTC 7863, indicating that platelet aggregation is fibrinogen dependent. These data suggest that platelet aggregation by some strains of S. sanguis requires multiple stimuli/agonists, including IgG-Fc receptor interaction, complement and fibrinogen.

Complement System Proteins