PubMed HealthSearch

PubMed · 505062

[Phenobarbital determination using direct densitometry of thin-layer chromatography].

Abstract

A report on the determination of phenobarbital in model specimens of plasma and blood using direct densitometry of thin-layer chromatograms, namely by measurements of fluorescence quenching using remission technique following previous conversion of phenobarbital to sodium salt. Phenobarbital is extracted by three fundamentally different techniques, the results of estimation are given statistical evaluation, and the yield of each of the techniques is compared. Since the processing of 1 ml serum still allows the estimation of quantities as low as 1 microgram per stain the proposed method can be recommended for the determination of toxic levels of phenobarbital in plasma or in blood.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Kosatik. 1979. [Phenobarbital determination using direct densitometry of thin-layer chromatography].. https://pubmed.ncbi.nlm.nih.gov/505062/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Spectrofluorimetric determination of dipyridamole in serum--a comparison of two methods.

Two spectrofluorimetric methods for the determination of dipyridamole in plasma are described. The thin-layer chromatographic-fluoridensitometric method utilizes 1 ml of plasma which is extracted at pH 10 with diethyl ether-dichloromethane (80:20). The organic phase is evaporated to dryness, reconstituted in 250 microliter dichloromethane and 5 microliter are spotted on a silica gel 60 plate. The plate is developed in ethyl acetate-methanol-ammonia (85:10:5), dried, dipped in a paraffin wax solution, dried, and scanned using 380 nm as excitation wavelength, a 430 nm cut-off filter, and collecting all emitted light on the photomultiplier. Quantitation was done by the external standard method, peak heights being measured and a calibration graph constructed. For the spectrofluorimetric method 1 ml of plasma is extracted at pH 10 with 8 ml of hexane-isoamyl alcohol (95:5) and the organic phase used directly for the measurement of the fluorescence intensity (excitation 405 nm, emission 495 nm). Quantitation was done by measuring the fluorescence of standards that were treated as above and constructing a calibration graph of concentration versus fluorescence intensity. Concentrations of unknowns were found by interpolation from this graph. The two methods were found to exhibit good correlation but the spectrofluorimetric method proved to be more amenable to the analysis of a large number of samples.

Chromatography, Thin Layer