PubMed HealthSearch

PubMed · 5204279

[Problems in fluid balance].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H J Krecke. 1971. [Problems in fluid balance].. https://pubmed.ncbi.nlm.nih.gov/5204279/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design and evaluation of an automated solid-phase extraction method development system for use with biological fluids.

An automated solid-phase extraction method development system, utilizing a Zymate XP robot and a custom-designed solid-phase extraction manifold, has been developed and validated. This system spikes blank liquid matrix, such as plasma, with solutions containing drug, internal standard, and up to three metabolites. Samples are then buffered or diluted with an appropriate reagent. After these samples and corresponding blanks have been prepared, solid-phase cartridges containing selected sorbents are automatically conditioned. Samples are robotically vortexed and transferred to the conditioned cartridges, and analytes are extracted. Validation of this robotic system demonstrated acceptable precision and accuracy for three types of liquid transfer, including metering pump ( < 6% RSD and RE for > or = 2.0 mL dispensation), syringe-based laboratory station ( < or = 2.9% RSD and 0.5% RE for volumes between 0.25 and 1.00 mL), and syringe hands ( < 3.5% RSD and RE for volumes between 0.10 and 1.00 mL). For two example compounds, the system provided data which effectively distinguished good solid-phase sorbents from marginal ones through precision, recovery, and chromatographic selectivity. Solid-phase extraction of these compounds from human plasma gave precision (2-10% RSD) and extraction efficiency (96 +/- 6%) comparable to results obtained from manual extractions (92 +/- 11%).

Body Fluids

Comparison of Cyto-Shuttle and cytocentrifuge as processing methods for nongynecologic cytology specimens.

The Cyto-Shuttle (Cancer Diagnostics, Inc., Fairfax, VA) monolayer preparation method was compared to our routine cytocentrifuge method in 129 fluid cytology cases. A single sample from each case was split and prepared by each method. The Cyto-Shuttle preparation was superior to the cytocentrifuge preparation in 51% of cases, equal to it in 38%, and inferior to it in 11%: bronchial wash/lavage (45 cases), 38%, 49%, 13%; body cavity fluid (39 cases), 72%, 15%, 13%; urine (18 cases), 56%, 44%, 0%: peritoneal washing (16 cases), 44%, 44%, 12%; and miscellaneous (11 cases), 36%, 55%, 9%. Cyto-Shuttle preparations were superior due to decreased background and increased number of cells per slide; fixation and morphology were generally equivalent to cytocentrifuge preparations.

Body Fluids