A closed technique for repositioning dislocated iris plane lenses.

Abstract

Of 450 iris plane IOL's implanted over a 3 1/2-year period, 20 (5%) dislocated. Four of these lenses dislocated into the vitreous and were either floated or surgically reoriented into the anterior chamber to give final visual acuities of 20/30 or better. Sixteen lenses dislocated into the anterior chamber and were repositioned using a closed bimanual technique. After lens repositioning, eighteen eyes achieved 20/30 or better vision. One eye's vision was 20/200 and another case had finger-counting vision.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B J Poley, D P Le Win. 1979. A closed technique for repositioning dislocated iris plane lenses.. https://doi.org/10.1016/s0146-2776(79)80082-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Model of pulsatile-flow of aqueous humor through the iris-lens canal.

PURPOSE: To present a model of pulsatile-flow of aqueous humor from posterior (PC) to anterior chamber (AC) and to analyze the sensitivity of this novel model in detecting typical high risk conditions predisposing to pupillary block. METHODS: The model assumes noncontinuous flow of aqueous through the iris-lens canal. Aqueous that fills the canal will be ejected toward the AC-side of the canal at certain time intervals, and between 2 events of aqueous ejection there is no actual flow through this canal. Pupillary pumping rate (PPR) was calculated from the aqueous flow rate and the calculated volume of iris-lens canal. RESULTS: PPR values were generated by incorporating pupillary diameter (1 to 8 mm), aqueous flow rate (1 to 2.5 microL/min), and iris-lens canal width (0.5 to 2 mm) and height (3-9 microm) in numerical experimentation with the present model. PPR showed inverse dependence on iris-lens canal height and pupillary diameter and was directly proportional to aqueous flow rate, in agreement with the steady-flow model. However, contrary to the steady-flow model, PPR showed inverse dependence on iris-lens canal width and predicted the anticipated PC-AC pressure gradient changes at simulated light-dark transition in eyes of patients with clinically narrow angles and ultrasound biomicroscopy evidenced pupillary block. CONCLUSIONS: Upon the incorporation of real ultrasound biomicroscopy measurements in numerical experimentations with both models, the present pulsatile-flow model, contrary to the steady-flow model, showed good predictability of PC-AC pressure gradient changes in a typical condition predisposing to pupillary block.

Anterior Chamber↗