PubMed · 529036
Correlation of urinary excretion with in vitro dissolution using several dissolution methods for hydrochlorothiazide formulations.
Abstract
Four different hydrochlorothiazide formulations were prepared, and cumulative urinary hydrochlorothiazide excretion was determined in a crossover study using six volunteers. A comparison of in vivo results showed that one formulation (Forumulation D) was significantly different from the others at 2, 3, 4, 5, 8, and 14 hr. A dissolution study was conducted on each formulation using the flask, USP basket, and magnetic basket methods at agitation speeds of 50, 100, and 150 rpm. Formulation D was significantly different from other formulations when determined using the USP basket method at 150 rpm and a sampling time of 10 min; the USP basket method at 100 rpm and a sampling time of 100 min; the flask method at 100 rpm and sampling times of 30, 40, 60, and 120 min; and the flask method at 150 rpm and sampling times of 30 and 40 min. Significant in vitro and in vivo correlations were found using a regression analysis and F test. With a correlation coefficient and 95% confidence intervals, it was established that the USP basket method at 150 rpm was the best predictor of urinary hydrochlorothiazide excretion among the dissolution methods tested.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
K A Shah, T E Needham. 1979. Correlation of urinary excretion with in vitro dissolution using several dissolution methods for hydrochlorothiazide formulations.. https://doi.org/10.1002/jps.2600681206
Cite the original work for its findings. Save a collection to share your selection of sources.