PubMed HealthSearch

PubMed · 5322843

An improved method for fixing amoebae for electron microscopy.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D K Bhowmick, K E Wohlfarth-Bottermann. 1965. An improved method for fixing amoebae for electron microscopy.. https://doi.org/10.1016/0014-4827(65)90258-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In vivo expression of the nucleolar group I intron-encoded I-dirI homing endonuclease involves the removal of a spliceosomal intron.

The Didymium iridis DiSSU1 intron is located in the nuclear SSU rDNA and has an unusual twin-ribozyme organization. One of the ribozymes (DiGIR2) catalyses intron excision and exon ligation. The other ribozyme (DiGIR1), which along with the endonuclease-encoding I-DirI open reading frame (ORF) is inserted in DiGIR2, carries out hydrolysis at internal processing sites (IPS1 and IPS2) located at its 3' end. Examination of the in vivo expression of DiSSU1 shows that after excision, DiSSU1 is matured further into the I-DirI mRNA by internal DiGIR1-catalysed cleavage upstream of the ORF 5' end, as well as truncation and polyadenylation downstream of the ORF 3' end. A spliceosomal intron, the first to be reported within a group I intron and the rDNA, is removed before the I-DirI mRNA associates with the polysomes. Taken together, our results imply that DiSSU1 uses a unique combination of intron-supplied ribozyme activity and adaptation to the general RNA polymerase II pathway of mRNA expression to allow a protein to be produced from the RNA polymerase I-transcribed rDNA.

Amoeba

Cubic membrane structure in amoeba (Chaos carolinensis) mitochondria determined by electron microscopic tomography.

Cubic membranes occur in a variety of membrane-bound organelles in many cell types. By transmission electron microscopy (TEM) these membrane systems appear to consist of highly curved periodic surfaces that fit mathematical models analogous to those used to describe lipidic cubic phases. For the first time, a naturally occurring cubic membrane system has been reconstructed in three dimensions by electron microscopic tomography, and its periodicity directly characterized. Double-tilt tomographic reconstruction of mitochondria in the amoeba, Chaos carolinensis, confirms that their cristae (inner membrane infoldings) have the cubic structure suggested by modeling studies based on thin-section TEM images. Analysis of the membrane surfaces in the reconstruction reveals the connectivity of the internal compartments within the mitochondria. In the cubic regions, the matrix is highly condensed and confined to a continuous, small space between adjacent cristal membranes. The cristae form large, undulating cisternae that communicate with the peripheral (inner membrane) compartment through narrow tubular segments as seen in other types of mitochondria. The cubic periodicity of these mitochondrial membranes provides an ideal specimen for measuring geometrical distortions in biological electron tomography. It may also prove to be a useful model system for studies of the correlation of cristae-matrix organization with mitochondrial activity.

Amoeba

Microbiologic analysis of bottled water: is it safe for use with contact lenses?

OBJECTIVE: To analyze commercially available bottled water as a possible source of microbial contamination of contact lenses. METHODS: Two different lots of 23 brands of noncarbonated bottled water were tested for coliforms, total bacteria, fungi, and free-living amebae. A sample consisted of three separate 100-ml aliquots from one lot of each brand (46 samples). Aliquots were vacuum-filtered using a 0.45-microm Nalgene analytical filter unit, and the membrane filter was placed on a filter pad in a Petri dish containing test medium. Plates were examined under a stereomicroscope, and the number of colony-forming units (CFUs) was calculated for each sample. To test for the presence of free-living amebae, three aliquots totaling approximately 3800 ml were concentrated using 8-microm filters, and the filters were placed on non-nutrient agar with live Enterobacter aerogenes. To assess the possibility of contaminating contact lenses, etafilcon lenses were rinsed in 2-ml aliquots of four brands of bottled water and then cultured. RESULTS: Seventeen (37%) of 46 samples, representing 11 (48%) of 23 brands, contained viable micro-organisms. Bacteria, including coliforms, were recovered from 12 samples of 8 brands. Yeasts or molds were recovered from seven samples of five brands. Free-living amebae were isolated from two samples, and fresh-water algae were found in both samples of one brand. Nine (20%) of 46 samples, representing 7 (30%) of the 23 brands, had more than 500 CFUs per ml or contained coliforms. Sterile contact lenses became contaminated when exposed for 1 minute to two of four brands of water from which micro-organisms were recovered. CONCLUSION: Some bottled waters contain high numbers of potential ocular pathogens. Bottled water is not safe for routine use with contact lenses.

Amoeba