PubMed HealthSearch

PubMed · 5435210

Atrial function in man.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Talbot. 1970-02-28. Atrial function in man.. https://doi.org/10.1136/bmj.1.5695.567-c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Nature of dual atrioventricular node pathways and the tachycardia circuit as defined by radiofrequency ablation technique.

OBJECTIVES: A comprehensive electrophysiologic study followed by selective radiofrequency ablation from three sites was performed in patients with atrioventricular (AV) node reentrant tachycardia to better delineate the nature of the tachycardia circuit. BACKGROUND: We postulated that the retrograde fast pathway is the anterior superficial group of transitional cells and the slow pathway is the compact node with its posterior input of transitional cells. Twenty-three consecutive patients were studied. In nine, the atria could be dissociated from the tachycardia by delivery of an atrial extrastimulus during tachycardia. METHODS: Radiofrequency ablation was performed with three approaches. The anterior approach was designed to interrupt the anterior superficial atrial input to the compact node, the posterior approach to interrupt the posterior atrial input to the compact node and the inferior approach to destroy the compact node itself. RESULTS: Selective ablation of the retrograde fast pathway was achieved in seven patients, six with the anterior and one with the inferior approach. Anterograde fast pathway conduction was not affected, whereas retrograde fast pathway conduction was either abolished or markedly depressed. None had induction of echoes or tachycardia after ablation. Selective ablation of the slow pathway was successful in 13 patients, 1 with anterior, 3 with posterior and 9 with inferior approaches. In these 13 patients, both anterograde and retrograde fast pathway conduction were not affected, the dual pathway physiology was abolished and the tachycardia was not inducible after ablation. Ablation of both the retrograde fast pathway and the slow pathway occurred with the inferior approach in three patients. CONCLUSIONS: We conclude that the retrograde fast pathway is likely to be the anterior superficial group of transitional cells, whereas the slow pathway is the compact node and its posterior input of transitional cells. A barrier seems to exist between the atrium and the tachycardia circuit. In a broad view of the AV node structure, the tachycardia circuit is confined to the node.

Atrial Function

Calculation of atrioventricular compliance from the mitral flow profile: analytic and in vitro study.

The quantitative assessment of ventricular diastolic function is an important goal of Doppler echocardiography. Hydrodynamic analysis predicts that the net compliance (Cn) of the left atrium and ventricle can be quantitatively predicted from the deceleration rate (dv/dt) of the mitral velocity profile by the simple expression: Cn = - A/rho dv/dt, where A is effective mitral valve area and rho is blood density. This formula was validated using an in vitro model of transmitral filling where mitral valve area ranged from 0.5 to 2.5 cm2 and net compliance from 0.012 to 0.023 cm3/(dynes/cm2) (15 to 30 cm3/mm Hg). In 34 experiments in which compliance was held constant throughout the filling period, net atrioventricular compliance was accurately calculated from the E wave downslope and mitral valve area (r = 0.95, p less than 0.0001). In a second group of experiments, chamber compliance was allowed to vary as a function of chamber pressure. When net compliance decreased during diastole (as when the ventricle moved to a steeper portion of its pressure-volume curve), the transorifice velocity profile was concave downward, whereas when net compliance increased, the velocity profile was concave upward. Application of the preceding formula to these curved profiles allowed instantaneous compliance to be calculated throughout the filling period (r = 0.93, p less than 0.001). Numeric application of a mathematic model of mitral filling demonstrated the accuracy of this approach in both restrictive and nonrestrictive orifices.(ABSTRACT TRUNCATED AT 250 WORDS)

Atrial Function