PubMed HealthSearch

PubMed · 5469232

Elective neck dissection--1970.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G F Reed, W A Miller. 1970. Elective neck dissection--1970.. https://doi.org/10.1288/00005537-197008000-00011

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Dosimetric evaluation of the conformation of the multileaf collimator to irregularly shaped fields.

PURPOSE: The goal of this study was to evaluate the dosimetric characteristics of geometric MLC prescription strategies and compare them to those of conventional shielding block. METHODS AND MATERIALS: Circular fields, square fields, and 12 irregular fields for patients with cancer of the head and neck, lung, and pelvis were included in this study. All fields were shaped using the MLC and conventional blocks. A geometric criterion was defined as the amount of area discrepancy between the MLC and the prescription outline. The "least area discrepancy" (LAD) of the MLC conformation was searched by selecting the collimator angle, meanwhile keeping a preselected position along the width of the leaf into the prescribed field. Five LAD conventions were studied. These included the LAD-0, LAD-1/3, LAD-1/2, and LAD-2/3 that inserted the leaves at the 0, 1/3, 1/2, and 2/3 of the leaf end into the prescription field, respectively. In addition, the LAD optimization was applied to the transecting (TRN) approach for leaf conformation that prescribed an equal area of overblocking and underblocking under each leaf. Film dosimetry was performed in a 20 cm polystyrene phantom at 10 cm depth 100 cm from source to axis distance (SAD) for both 6 and 18 MV photons with each of the above MLC conformations and conventional blocks. The field penumbra width, defined as the mean of the separation between the 20% and 80% isodose lines along the normal of the prescription field edge, was calculated using both the MLC and conventional block film dosimetry and compared. In a similar way, the d20 is defined as the mean separation between the 20% isodose line and the prescription field edge, and the d80 is defined as the mean separation between the 80% isodose line and the prescription field edge. RESULTS: The field penumbra width for all MLC conventions was approximately 2 mm larger than that of the conventional block. However, there was a larger variation of the separation distribution in the penumbra region of the irregular fields for the MLC, which had a standard deviation of 1 mm (a factor of 5 larger than the conventional block). The dosimetry for the circular fields showed that the LAD-TRN, LAD-1/2, and LAD-1/3 approximated the conventional blocking well in terms of d20 and d80; however, no single convention produced the best conformation for both measures. The dosimetric result of the patient treatment fields was similar for all sites. The LAD-1/3, LAD-1/2, and LAD-TRN strategies conformed to within 1 to 1.5 mm of the d80 of the conventional block for both 6 MV and 18 MV, respectively. The LAD-1/2 and LAD-TRN conformations were virtually identical, although it is proven analytically that the LAD-1/2 convention has the least overall area discrepancy of all conventions. CONCLUSIONS: The five MLC conformation conventions resulted in similar dosimetric penumbrae for all field shapes studied. The LAD-1/3, LAD-TRN, and LAD-1/2 produced the more favorable approximation to conventional block. The field penumbra width, although useful for evaluating irregular field shapes, could not describe the large local variations in the penumbra along the field edge for the MLC. These local variations could be of clinical concern when they appear near vital organs. However, the variation in a local region can potentially be reduced by minimizing the jaggedness of the leaf steps in that local region. The dosimetric results were useful as guidelines for the clinicians in the evaluation and adjustment of MLC leaf positions.

Head and Neck Neoplasms

Three dimensional planning target volumes: a model and a software tool.

PURPOSE: Three dimensional (3D) target volumes are an essential component of conformal therapy because the goal is to shape the treatment volume to the target volume. The planning target volume (PTV) is defined by ICRU 50 as the clinical target volume (CTV) plus a margin to ensure that the CTV receives the prescribed dose. The margin must include all interfractional and intrafractional treatment variations. This paper describes a software tool that automatically generates 3D PTVs from CTVs for lung cancers and immobile head and neck cancers. METHODS AND MATERIALS: Values for the interfractional and intrafractional treatment variations were determined by a literature review and by targeted interviews with physicians. The software tool is written in Common LISP and conforms to the specifications for shareable software of the Radiotherapy Treatment Planning Tools Collaborative Working Group. RESULTS: The tool is a rule-based expert system in which the inputs are the CTV contours, critical structure contours, and qualitative information about the specific patient. The output is PTV contours, which are a cylindrical expansion of the CTV. A model for creating PTVs from CTVs is embedded in the tool. The interfractional variation of setup uncertainty and the intrafractional variations of movement of the CTV (e.g., respiration) and patient motion are included in the model. Measured data for the component variations is consistent with modeling the components as independent samples from 3D Gaussian distributions. The components are combined using multivariate normal statistics to yield the cylindrical expansion factors. Rules are used to represent the values of the components for certain patient conditions (e.g., setup uncertainty for a head and neck patient immobilized in a mask). The tool uses a rule interpreter to combine qualitative information about a specific patient with rules representing the value of the components and to enter the appropriate component values for that patient into the cylindrical expansion formula. CONCLUSION: The portable software tool allows the rapid, consistent, and automatic generation of 3D PTVs from CTVs.

Head and Neck Neoplasms