PubMed HealthSearch

PubMed · 5581738

A quality control program using the Coulter Counter Model S.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K L Overton. 1971. A quality control program using the Coulter Counter Model S.. https://pubmed.ncbi.nlm.nih.gov/5581738/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Processing and cryopreservation of placental/umbilical cord blood for unrelated bone marrow reconstitution.

Clinical evidence of hematopoietic restoration with placental/umbilical cord blood (PCB) grafts indicates that PCB can be a useful source of hematopoietic stem cells for routine bone marrow reconstitution. In the unrelated setting, human leukocyte antigen (HLA)-matched donors must be obtained for candidate patients and, hence, large panels of frozen HLA-typed PCB units must be established. The large volume of unprocessed units, consisting mostly of red blood cells, plasma, and cryopreservation medium, poses a serious difficulty in this effort because storage space in liquid nitrogen is limited and costly. We report here that almost all the hematopoietic colony-forming cells present in PCB units can be recovered in a uniform volume of 20 ml by using rouleaux formation induced by hydroxyethyl starch and centrifugation to reduce the bulk of erythrocytes and plasma and, thus, concentrate leukocytes. This method multiples the number of units that can be stored in the same freezer space as much as 10-fold depending on the format of the storage system. We have also investigated the proportion of functional stem/progenitor cells initially present that are actually available to the recipient when thawed cryopreserved PCB units are infused. Progenitor cell viability is measurably decreased when thawed cells, still suspended in hypertonic cryopreservative solutions, are rapidly mixed with large volumes of isotonic solutions or plasma. The osmotic damage inflicted by the severe solute concentration gradient, however, can be averted by a simple 2-fold dilution after thawing, providing almost total recovery of viable hematopoietic progenitor cells.

Blood Cell Count

Variability in clinical systems: applying modern quality control methods to health care.

BACKGROUND: Quality health care depends on timely completion of sequences of clinical care. This study evaluated the concepts and tools of quality management for measuring system performance in ambulatory care. STUDY DESIGN: Clinical staff in nine centers of a group model health maintenance organization described the procedure for ordering and completing a complete blood count, mammogram, and surgical consultation. Variability was noted among the processes as intended and as actually performed, as well as inconsistencies reported within and among centers. In two centers investigators tracked performance of key sequences of care and the achievement of other key quality characteristics believed desired by physicians and patients. Computerized patient records and departmental files were the only available sources of data for assessing completion and followup of tests and consultations. Even these data were difficult to obtain and, in many instances, incomplete. RESULTS: Although data were often difficult to obtain, the quality management techniques used were helpful in revealing process failures that appeared to be the result of design flaws built into the clinical systems. CONCLUSION: Robust process designs and improved management information systems for monitoring these processes are recommended to reduce variability and improve the quality of clinical care.

Blood Cell Count

[The therapy of the heparin-induced thrombosis-thrombocytopenia syndrome with immunoglobulins].

A 51-year-old obese woman who had just undergone a second osteotomy for arthrosis of the hip joint was given unfractionated heparin, 7,500 IU subcutaneously three times daily, as thrombosis prophylaxis. Signs of fulminant pulmonary embolism occurred on the 16th postoperative day with a platelet count of 33,000/microliters. Suspected heparin-induced thrombocytopenia and thrombosis (HITT) was confirmed by platelet tests. When heparin had been discontinued immunoglobulin G was administered, seven times 5 g intravenously, in view of the immunological genesis of HITT. In addition thrombolysis treatment with streptokinase combined with phenprocoumon was undertaken, until satisfactory anticoagulation was achieved after 4 days. Platelet count rose to 136,000/microliters within 20 hours of the first immunoglobulin dose. Complete clinical normality was restored, scintigraphy showed no perfusion deficit in the lungs.

Blood Cell Count