Solid-state energy-dispersion spectrometer for electron-microprobe x-ray analysis.

Abstract

Improved lithium-drifted silicon solid-state detectors allow detection and energy dispersion of x-rays of about 3 to 30 kiloelectron volts in the electron-microprobe x-ray analyzer. Energy resolution is sufficient to separate peaks of characteristic x-rays of elements adjacent in the periodic system at atomic number 20 and higher. The detected x-ray spectrum emitted from an unknown sample can be recorded with a multichannel analyzer in approximately 60 seconds.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Fitzgerald, K Keil, K F Heinrich. 1968-02-02. Solid-state energy-dispersion spectrometer for electron-microprobe x-ray analysis.. https://doi.org/10.1126/science.159.3814.528

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Molybdenum-free nitrate reductases from vanadate-reducing bacteria.

Two catalytically distinct molybdenum-free dissimilatory nitrate reductases, a soluble periplasmic and a membrane-bound one, were isolated from the vanadate-reducing facultatively anaerobic bacterium Pseudomonas isachenkovii and purified to electrophoretic homogeneity. The enzymes did not contain molybdenum, the periplasmic enzyme contained vanadium, whereas the membrane-bound enzyme was vanadium-free. Both nitrate reductases lacked molybdenum cofactor. This fact was proved by reconstitution of the apoprotein of the nitrate reductase of Neurospora crassa nit-1 mutant. This is the first demonstration of molybdenum-free and molybdenum cofactor-free nitrate reductases.

Electron Probe Microanalysis

Effect of surface treatment on unalloyed titanium implants: spectroscopic analyses.

Surgical implant finishing and sterilization procedures were investigated to determine surface characteristics of unalloyed titanium (Ti). All specimens initially were cleaned with phosphoric acid and divided into five groups for comparisons of different surface treatments (C = cleaned as above, no further treatment; CP = C and passivated in nitric acid; CPS = CP and dry-heat sterilized; CPSS = CPS and resterilized; CS = C and dry-heat sterilized). Auger (AES), X-ray photoelectron (XPS), and Raman spectroscopic methods were used to examine surface compositions. The surface oxides formed by all treatments primarily were TiO2, with some Ti2O3 and possibly TiO. Significant concentrations of carbonaceous substances also were observed. The cleaning procedure alone resulted in residual phosphorus, primarily as phosphate groups along with some hydrogen phosphates. A higher percentage of physisorbed water appeared to be associated with the phosphorus. Passivation (with HNO3) alone removed phosphorus from the surface; specimens sterilized without prior passivation showed the thickest oxide and phosphorus profiles, suggesting that passivation alters the oxide characteristics either directly by altering the oxide structure or indirectly by removing moieties that alter the oxide. Raman spectroscopy showed no crystalline order in the oxide. Carbon, oxygen, phosphorus, and nitrogen presence were found to correlate with previously determined surface energy.

Electron Probe Microanalysis

Technique for identification of submicron metal particulate from implants in histological specimens.

Metal implants are being used with increasing frequency for the treatment of many diseases in the field of orthopedics, cardiology, cardiovascular surgery, and otolaryngology. Unfortunately, metals can be a source of submicron particles, which may have adverse effects on tissues. This article describes a technique that uses backscattered electron imaging and energy dispersive X-ray microanalysis, which have the capacity to perform both quantitative and qualitative analysis. The particles can be characterized by size, shape, amount, and composition. Although this technique can be used near the implant interface, it is particularly helpful in tissues a great distance from the implant site with a low concentration of metal debris. In addition, the sensitivity and specificity of this technique can be adjusted to the investigator's needs.

Electron Probe Microanalysis