PubMed HealthSearch

PubMed · 5649382

Early ambulation aid.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Bodenheim, N Bodenstein. 1968. Early ambulation aid.. https://doi.org/10.1093/ptj%2F48.4.353

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Accuracy and precision of volumetric determinations using two commercial CAD systems for prosthetics: a technical note.

The aim of this study was to evaluate the validity and reliability of volume determinations using the commercially available Seattle ShapeMaker CAD/CAM system for production of prosthetic sockets and to compare it with the commercially available CAPOD system. We used three types of reference objects for volumetric determinations: steel tubes, plaster of Paris casts, and residual limb models. Three different sizes were examined for each type of object. Volume measurements with the two CAD/CAM systems were compared with measurements obtained by water filling, water immersion, or mathematical calculation (tubes only). We found an inconsistent systematic error of less than 3.1% for ShapeMaker and no systematic error for CAPOD. Random errors, represented by the coefficient of variation, were below 1.3% for the ShapeMaker and, in most cases, below 0.4% for the CAPOD. Theoretical changes in volume of 2.6% and 0.8% are possible to detect with these CAD/CAM systems. In our opinion, both systems have sufficient precision for routine clinical use in prosthetics and orthotics. However, in our study, the ShapeMaker committed larger random and systematic errors than CAPOD. This means that, according to our study, CAPOD offers the best possibility to determine and detect small changes in residual limb volume as a function of time.

Artificial Limbs

Methods for reducing energy dissipation in cosmetic gloves.

For cosmetic reasons, hand prostheses are provided with cosmetic gloves. Their pleasing appearance, however, is accompanied by poor mechanical behavior, resulting in a negative influence on prosthesis operation. Glove stiffness is high and nonlinear, and internal friction in the glove material causes energy dissipation (hysteresis). In this article, two methods for reducing hysteresis in cosmetic gloves are proposed, that may be applied independently or in combination. Glove modification. Altering the mechanical properties of the glove itself is the first method that is presented. It was found possible to reduce both stiffness and hysteresis about 50% by forming grooves into the inside of the glove. Together with the evaluation of this method, several properties of the cosmetic glove were determined. Motion optimization. Additionally, a second method for reducing hysteresis was developed. The amount of hysteresis is influenced by the way the glove is forced to deform. The prosthesis mechanism, determining this deformation, was designed for minimum hysteresis and maximum cosmesis. For the prosthesis-glove combination used in this study, thumb motion optimization reduced hysteresis by about 65%.

Artificial Limbs