PubMed Health⌕ Search

PubMed · 5784292

Rod increment thresholds on steady and flashed backgrounds.

Abstract

1. This paper presents increment threshold data for a fairly wide range of parameters but certain of the relationships are slightly complicated by what may amount to large differences in the observers' criterion. The following paper deals with a very limited range of parameters but the measurements are more precise and the analysis more simple.2. Increment thresholds have been measured for a small, brief duration test viewed against large steady and pulsed backgrounds, using the technique of Aguilar & Stiles (1954) which is intended to isolate rod vision. Under these circumstances it is shown that the test is seen by the rods and that the cones do not disturb the sensitivity of the rods.3. The relative positions of increment threshold curves for steady and pulsed backgrounds are usually consistent with an integration time of tau = ca. 0.1 sec.4. Backgrounds of less than 0.1 sec duration are effectively impulse inputs in the sense that the magnitude and time course of the test threshold disturbance (;impulse function') is dependent only on background energy.5. Functions of the impulse function may be substituted for the classical integration time tau. The exact form of the impulse function and its theoretical treatment is pursued in the next paper.6. The threshold disturbance caused by switching on a background light settles to a steady value within 2 to 3 times tau.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P E Hallett. 1969. Rod increment thresholds on steady and flashed backgrounds.. https://doi.org/10.1113/jphysiol.1969.sp008816

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

LED-generated multifocal ERG on- and off-responses in complete congenital stationary night blindness -- a case report.

We report on the application of a light emitting diode (LED) screen to elicit multifocal ERG on- and off-responses in a patient presenting with the complete type of congenital stationary night blindness (cCSNB): A 63-years old woman was diagnosed with cCSNB by means of standard ERG procedures and dark adaptometry. To confirm this diagnosis and to investigate topographical differences of on- and off-responses a multifocal approach employing long-duration stimuli was added. Results of mfERG-testing were averaged in three groups (a central area of 7.5 degrees , a ring area of 7.5-21.9 degrees and a peripheral ring of 21.9-31.1 degrees ). When compared to normal controls (n = 4) on-responses (P1-amplitudes) were severely reduced symmetrically at all eccentricities, while off-responses showed no reduction resulting in an increased off/on-ratio. Furthermore on-latencies of P1 were delayed symmetrically at all eccentricities, whereas off-latencies were normal. To our knowledge this is the first report of multifocal on- and off-responses in a CSNB-patient. Stimulus-generation with a LED-screen provides the advantage of a stable luminance during the long-duration on-phase.

Dark Adaptation↗

Is the spectacle lens jack-in-the-box phenomenon really due to the lenses?

The calculation of the extent of the ring scotoma around positive lenses, as conventionally taught to students of clinical optics, indicates that the scotoma is of a significant size. Using knife-edge lenses this study shows that the calculations are invalid due to the finite size of the eye's entrance pupil and in many instances the scotoma is shown not to exist. The effect noticed in clinical practice is probably largely due to the frame and the edging techniques used which add to the refractive scotoma which is present with high powered lenses, large apertures and/or small pupil sizes.

Dark Adaptation↗