PubMed HealthSearch

PubMed · 5784293

Impulse functions for human rod vision.

Abstract

1. This paper presents accurate increment threshold data for human rod vision for a small number of experimental parameters. The test is small and brief and the large background is either steady or transient.2. The linear threshold disturbance due to an impulse background consists of an input dependent exponential growth phase and an exponential recovery phase of more or less fixed time constant (ca. 0.08 sec).3. The data are treated by applying signal/noise decision theory to a hypothetical filter with two shot noise inputs, viz. the testing signal and the background. The gain and time course of the impulse function of the filter are slightly affected by the magnitude of the input.4. A linear approach is useful since the impulse functions for dark or light-adapted rod vision yield independent information about quantities which have previously only been used to describe the increment thresholds for small tests on steady backgrounds, viz. the integration time and dark light of the fully dark-adapted eye and the gain changes (or changes in the signal/background ratio) which occur on progressive light adaptation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P E Hallett. 1969. Impulse functions for human rod vision.. https://doi.org/10.1113/jphysiol.1969.sp008817

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The roles of polarity and symmetry in the perceptual grouping of contour fragments.

We describe two experiments that investigate the roles of polarity and symmetry in the perceptual grouping of contour fragments. Observers viewed, for one second on each presentation, arrays of oriented, spatial-frequency band-pass, elements, in which a subset of the elements was aligned along a twisting curve. In each of five conditions we measured observers' ability to detect aligned combinations of even- and odd-symmetric elements, of the same and different polarities, against a background of 'noise' elements. As with previous experiments we found that the 'path' could be reliably detected, even when the elements of the path were oriented at angles of up to +/- 60 deg relative to each other. Detection of the path was still possible when the polarity of path elements alternated. However, the probability of detection of the path was raised significantly when the path elements were all of the same polarity. Perceptual grouping of even-symmetric elements was no different to perceptual grouping of odd-symmetric elements. The results provide evidence, that in achieving integration of contour fragments, the visual system uses a process that is to some degree phase selective. We use the results to describe how the visual system may resolve natural contours when they occur against backgrounds that vary over a wide range of intensities. The data presented here have been published in conference-abstract form (Hayes et al., 1993; Field et al., 1997).

Dark Adaptation

Testing optimum viewing conditions for mammographic image displays.

The viewbox luminance and viewing room light level are important parameters in a medical film display, but these parameters have not had much attention. Spatial variations and too much room illumination can mask real signal or create the false perception of a signal. This presentation looks at how scotopic light sources and dark-adapted radiologists may identify more real diseases.

Dark Adaptation

Electrophysiological evaluation of visual loss in Müller cell sheen dystrophy.

AIMS: To describe the clinical picture and electrophysiological findings in Müller cell sheen dystrophy, a recently reported retinal dystrophy. METHOD: A basic ophthalmological evaluation as well as recording of standard electro-oculography and electroretinography were performed in one patient at the onset of visual loss and after 1 year of follow up. RESULTS: A 61 year old woman presented with visual loss in the right eye. Multiple folds at the level of the internal limiting membrane were seen at the posterior pole in both eyes. Macular oedema was present in the right eye. The visual acuity of the right eye was 6/30 and of the left 6/9. A paracentral scotoma was found in the right eye. Electro-oculographic examination of both eyes gave normal results. Electroretinography (ERG) revealed reduced b-wave and flicker amplitudes in the right eye; these potentials were normal for the left eye. The ON response in the right eye was reduced and delayed; it was normal in the left eye. A further loss of visual function was noted 1 year later in the right eye, but the ophthalmoscopic findings were unchanged. The ERG of the right eye had a negative waveform when dark adapted. Light adapted responses showed an unusual delayed b-wave, broad and delayed ON and OFF responses and a missing flicker response, suggesting a Müller cell dysfunction. Light adapted responses were slightly reduced in the left eye. CONCLUSIONS: Electrophysiological data indicate Müller cell dysfunction as a background of functional loss in Müller cell sheen dystrophy. This is in agreement with previously reported histological findings in this disorder.

Dark Adaptation