PubMed Health⌕ Search

PubMed · 5784295

Quantum efficiency and false positive rate.

Abstract

1. This paper presents an analysis of the efficiency of performance at the absolute threshold of human vision. The data are from the same series as the previous papers (Hallett, 1969b, c) and consist of frequency-of-seeing curves, thresholds, false positive rates and equivalent background measurements, accumulated as small samples over a number of days.2. Quantum efficiency is defined here as the ratio of the thresholds of an ideal and a real detector performing the same task with the same sampling error. This avoids the problem as to whether the frequency-of-seeing curve of the real detector is exactly a Poisson sum or not.3. The long-term quantum efficiency can be low (about 0.04) as a result of drifts in the mean threshold.4. The average short-term quantum efficiency is in the region of 0.1, which is roughly the physiological limit set by Rushton's (1956b) measurements of rhodopsin density in the living rods. If this is correct, then the absorption of a quantum, and not the bleaching of a rhodopsin molecule, is sufficient for the generation of a neural event.5. Application of a simple signal/noise theory to the data gives solutions close to those suggested by Barlow (1956) and shows that false positives almost invariably arise from errors subsequent to the signal/noise decision process.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P E Hallett. 1969. Quantum efficiency and false positive rate.. https://doi.org/10.1113/jphysiol.1969.sp008819

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

LED-generated multifocal ERG on- and off-responses in complete congenital stationary night blindness -- a case report.

We report on the application of a light emitting diode (LED) screen to elicit multifocal ERG on- and off-responses in a patient presenting with the complete type of congenital stationary night blindness (cCSNB): A 63-years old woman was diagnosed with cCSNB by means of standard ERG procedures and dark adaptometry. To confirm this diagnosis and to investigate topographical differences of on- and off-responses a multifocal approach employing long-duration stimuli was added. Results of mfERG-testing were averaged in three groups (a central area of 7.5 degrees , a ring area of 7.5-21.9 degrees and a peripheral ring of 21.9-31.1 degrees ). When compared to normal controls (n = 4) on-responses (P1-amplitudes) were severely reduced symmetrically at all eccentricities, while off-responses showed no reduction resulting in an increased off/on-ratio. Furthermore on-latencies of P1 were delayed symmetrically at all eccentricities, whereas off-latencies were normal. To our knowledge this is the first report of multifocal on- and off-responses in a CSNB-patient. Stimulus-generation with a LED-screen provides the advantage of a stable luminance during the long-duration on-phase.

Dark Adaptation↗

Is the spectacle lens jack-in-the-box phenomenon really due to the lenses?

The calculation of the extent of the ring scotoma around positive lenses, as conventionally taught to students of clinical optics, indicates that the scotoma is of a significant size. Using knife-edge lenses this study shows that the calculations are invalid due to the finite size of the eye's entrance pupil and in many instances the scotoma is shown not to exist. The effect noticed in clinical practice is probably largely due to the frame and the edging techniques used which add to the refractive scotoma which is present with high powered lenses, large apertures and/or small pupil sizes.

Dark Adaptation↗