PubMed HealthSearch

PubMed · 5803603

Fluorescent thyroid scanning.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P B Hoffer. 1969. Fluorescent thyroid scanning.. https://doi.org/10.2214/ajr.105.4.721

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Development of a shielded 241Am applicator for continuous low dose rate irradiation of rat rectum.

This paper describes the development of sources, applicators, and techniques that can be used to irradiate rat rectums with continuous irradiation at dose rates of interest in brachytherapy, either with the full circumference of the rectum irradiated, or with half of the circumference shielded from the radiation. The system uses encapsulated 241Am sources, to irradiate rat rectum with 60 keV photons continuously at a dose rate of up to 50 cGy/hr. Details of the design and fabrication of the 241Am sources, the rectal applicator, the dosimetry of the system, and the protocols for preparing and irradiating the rats, and for detecting early rectal injury using histological examination of irradiated rectum are presented. Highly effective shielding (attenuation factors as low as 0.04) of half of the circumference of the rat rectum was achievable. Unidirectional 241Am irradiators for intracavitary brachytherapy offer a unique tool for examining the effects of shielding a portion of the circumference of the rat rectum, on the radiation tolerance of the rectum.

Americium

A comparison of radial dose functions for 103Pd, 125I, 145Sm, 241Am, 169Yb, 192Ir, and 137Cs brachytherapy sources.

Recently, encapsulated sources of 103Pd (21 keV average), 145Sm (41 keV average), 241Am (60 keV), and 169Yb (93 keV average) have been introduced as alternatives to conventional brachytherapy sources of 125I Model 6711 (27 keV average), 125I Model 6702 (28 keV average), 192Ir (369 keV average), and 137Cs (662 keV). To illustrate the dependence of the penetrating ability of photons from brachytherapy sources as a function of photon energy, a comparison of their radial dose functions is presented. Using the ITS Monte Carlo simulation code for photon-electron transport, the radial dose functions were calculated for monoenergetic photon sources with energies in the range of 30 keV to 1 MeV. Also, similar calculations were performed using the photon spectra emitted by the encapsulated brachytherapy sources. To verify the accuracy of Monte Carlo calculations, comparisons are made with our new measured data for 241Am and existing experimental and theoretical data from other investigators. A comparison of radial dose functions indicates that for 241Am, 169Yb, 192Ir and 137Cs sources radial dose functions are close to unity for distances up to 10 cm, for 145Sm the radial dose function drops to about 0.4 at 10 cm, and for 125I and 103Pd it drops precipitously to less than 0.20 at 7 cm. At 5 cm, the measured radial dose functions for 103Pd, 125I Model 6711, 125I Model 6702, 145Sm, 241Am, and 192Ir have values of 0.09, 0.34, 0.38, 0.86, 1.12, and 0.97, respectively. While all of these radioisotopes provide adequate penetrating power for interstitial brachytherapy, only the radioisotopes emitting photons with energies greater than about 40 keV can provide adequate depth dose (that is, small or no tissue attenuation) for intracavitary irradiation. Our criterion for choice of minimum photon energy suitable for intracavitary irradiation is that the radial dose function at 5 cm should not be less than 0.90. Also, note that photons with energies around 80 keV exhibit maximum penetrating ability in solid water for distances up to 5 cm.

Americium

Cytotoxicity, uptake and dissolution of 241AmO2 particles in dog alveolar macrophages in vitro.

Because alveolar macrophages play a role in the pulmonary clearance of inhaled particles, experiments were conducted to investigate the toxicity of 241AmO2 particles to alveolar macrophages and the role of these macrophages in the dissolution of 241AmO2 particles. Beagle dog pulmonary alveolar macrophages obtained by bronchopulmonary lavage were exposed in vitro to selected concentrations of 241AmO2. Macrophage viability determined by trypan-blue dye exclusion technique and the ability of the alveolar macrophages to phagocytose opsonized sheep red blood cells were the measures of 241AmO2 toxicity. The uptake of 241AmO2 particles was studied as a function of time. In addition, the dissolution of 241AmO2 by macrophages was determined for periods up to 72 h. After 20 h exposure to concentrations of 241Am higher than 4.63 kBq/ml, the phagocytic ability of macrophages was reduced, whereas no significant change in cell viability was observed at this concentration. Significant cell killing occurred at concentrations higher than 18.5 kBq/ml. After 72 h in the cultures, 10% of the 241AmO2 was dissolved by the alveolar macrophages. These findings imply that the inhalation of radioactive particles such as 241AmO2 particles might cause a reduction in the alveolar macrophage population in the lungs. In addition, the dissolution of 241AmO2 particles by alveolar macrophages might play a role in the short-term pulmonary clearance of inhaled 241AmO2 particles in the beagle dog.

Americium