PubMed Health⌕ Search

PubMed · 5908080

Catecholamines in human plasma.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J F O'Hanlon. 1966-02-11. Catecholamines in human plasma.. https://pubmed.ncbi.nlm.nih.gov/5908080/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of computer terminals on wards to access emergency test results: a retrospective audit.

OBJECTIVE: To assess delay in clinicians obtaining emergency biochemistry test results when the telephoning of results by laboratory staff is supplanted by installation of computer ward terminals. DESIGN: Retrospective observational study. SETTING: Accident and emergency department and acute medical admissions ward of a teaching hospital. SAMPLE: 3228 emergency requests for biochemistry tests sent from the accident and emergency department and 1836 from the medical admissions ward during August 1999 to January 2000 when there was no recorded telephone contact for results. MAIN OUTCOME MEASURES: Proportion of emergency biochemistry results accessed via a ward terminal within 1 or 3 hours of becoming available and the proportion never seen by this means. RESULTS: The results from 1443/3228 (45%) of urgent requests from accident and emergency and 529/1836 (29%) from the admissions ward were never accessed via the ward terminal. Results from 794/3228 (25%) of accident and emergency requests and 413/1836 (22%) of admissions ward requests were seen within 1 hour of becoming available while a further 491/3228 (15%) and 341/1836 (19%) respectively were accessed between 1 and 3 hours. In up to 43/1443 (3%) of the accident and emergency test results that were never looked at the findings might have led to an immediate change in patient management. CONCLUSIONS: When used as the sole substitute for telephoning results, the provision of terminal access to laboratory results on wards can hinder rather than promote the communication of emergency blood results to healthcare staff.

Blood Chemical Analysis↗

A clinical trial on a plate? The potential of 384-well format solid phase extraction for high-throughput bioanalysis using liquid chromatography/tandem mass spectrometry.

The application of 384-well format solid phase extraction (SPE) for bioanalysis using liquid chromatography/tandem mass spectrometry (LC/MS/MS) is reported and a 384-well SPE method for the 5-HT agonist sumatriptan in human plasma described. Plasma samples were extracted on a prototype low-density polyethylene 384-well SPE block using a packed bed of 5 mg Oasistrade mark HLB. Liquid handling was automated by a combination of a robotic sampler processor and a 96/384 multi-channel dispensing station. Samples and SPE reagents were drawn through the SPE block by centrifugation. The extracts were analysed by LC/MS/MS with thermally and pneumatically assisted electrospray ionisation and selected reaction monitoring. The method is used to illustrate and discuss the feasibility and viability of sample preparation techniques in high-density microtitre plate format for routine bioanalysis.

Blood Chemical Analysis↗

Electroosmosis injection of blood serum into biocompatible microcapillary chip fabricated on quartz plate.

A chip which allows the detection of various human health markers from a trace amount of blood has been studied. As a goal, a microcapillary with a 30 x 30 microm cross-section was fabricated using all-dry etching technologies on a 2 x 2 cm SiO2 chip. The coating of the biocompatible 2-methacryloyloxyethylphosphorylcholine (MPC) polymer on the inner quartz wall of the microcapillary demonstrated a sufficiently long adsorption suppression of proteins in the serum on the quartz surface, while rapid stopping occurred for serum injected into the microcapillary with a bare quartz surface. The latter rapid stopping corresponded well to fast electroosmosis flow due to the negatively increasing zeta-potential by the adsorption of proteins on the quartz surface. The electroosmosis pump arranged a downstream of the microcapillary was also developed to inject serum into it. As a preliminary application, a given concentration-standard solution was injected into the ion-sensitive field-effect transistor (ISFET) embedded in the chip, employing the electroosmosis pump arranged downstream of the sensor position. Hence, the pH and Na+ and K+ cation concentrations were measured.

Blood Chemical Analysis↗