PubMed HealthSearch

PubMed · 6033392

Percutaneous arterial catheterization for multiple sampling.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Moran, A R Lorimer, G Boyd. 1967. Percutaneous arterial catheterization for multiple sampling.. https://doi.org/10.1136/thx.22.3.253

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A prospective randomized study of 4.1 French catheters utilizing the percutaneous right brachial approach for the diagnosis of coronary artery disease.

To determine the utility of 4.1 French (F) catheters in diagnosing coronary artery disease, 50 patients were randomized to 4.1F Multipurpose or Judkins catheters utilizing the percutaneous right brachial approach. The randomized 4.1F tip shape catheter completed the procedure in 40% of the patients, and overall the 4.1F catheters completed the catheterization in 72% of the cases. With excessive or prolonged manipulation, the catheters were noted to kink and soften and required replacement for a catheter of similar or larger size. In 28% of the cases, larger F sizes (5F and 6F) were used to complete the procedure. There was 1 (2%) procedural complication. The total procedural success (accounting for all F sizes) without clinical complication was 98%. There was no difference between the 4.1F Judkins or Multipurpose catheter shapes for coronary arteriography by either qualitative or quantitative angiographic analysis. Left ventricular opacification was improved with the 4.1F Pigtail vs. the 4.1 Multipurpose by qualitative angiographic analysis. When the 4.1F angiograms were compared by quantitative angiography in blinded, but not randomized fashion to angiograms performed with 6F Judkins catheters, there was improved opacification of the LAD and diastolic frame of the left ventriculogram with the larger catheter. This difference was not noted with qualitative angiography. This study indicates that 4.1F catheters can be utilized from the right brachial approach for the diagnosis of coronary artery disease, thus avoiding the need for supine bedrest associated with routine femoral artery catheterization while maintaining diagnostic accuracy.

Brachial Artery

Radial artery cannulation: a comparison of 15.2- and 4.45-cm catheters.

Eighty-nine patients were studied prospectively to compare the incidence of postdecannulation arterial thrombosis and ischemic complications associated with percutaneous insertion of two different radial artery catheters. Patients scheduled for peripheral vascular surgery were randomized to receive a 15.2-cm (6 in, Argon Medical Corp.) or 4.45-cm (1.75 in, Arrow International, Inc.) 20-gauge, Teflon catheter. Extremity blood flow was evaluated prior to cannulation and again after decannulation with the modified Allen's test, pulse-volume plethysmography, and Doppler ultrasound. The incidence of postdecannulation radial artery occlusion for 15.2-cm catheters was significantly less than for 4.45-cm catheters (4 of 45 cases versus 11 of 44 cases, p = 0.05). No case of temporary or permanent ischemic injury occurred. Radial artery transfixion (16 of 45 cases versus 5 of 44 cases, p = 0.01) and hematoma formation (5 of 45 cases versus 0 of 44 cases, p = 0.02) occurred more frequently during insertion of 15.2-cm catheters than 4.45-cm catheters. The number of arterial punctures during catheter insertion and the duration of cannulation were similar for both groups. Of the 8 patients with positive modified Allen's test who underwent radial artery cannulation, one suffered arterial occlusion. Radial artery cannulation with a 15.2-cm catheter was associated with a lower incidence of postdecannulation radial artery thrombosis than cannulation with the 4.45-cm catheter. Radial artery cannulation with longer catheters (greater than 5.0 cm) appears to be a safe practice.

Brachial Artery