PubMed HealthSearch

PubMed · 6050644

A solid-state pre-amplifier with high input impedance.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Hodges, G Hollins. 1967. A solid-state pre-amplifier with high input impedance.. https://pubmed.ncbi.nlm.nih.gov/6050644/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Description and demonstration of a CMOS amplifier-based-system with measurement and stimulation capability for bioelectrical signal transduction.

An extracellular recording system incorporating an electrode array and an amplifier/stimulator CMOS chip is described and characterized. Important features of this custom VLSI chip include 16 instrumentation amplifiers with a gain of 50 and the incorporation of a cross-point array allowing designation of an extracellular microelectrode as either a stimulator or sensor. The planar array consisted of 32 microelectrodes, 14 microns in diameter, and four larger reference electrodes. Microelectrodes, interconnecting traces, and bond pads were patterned with a 500-nm layer of gold. The interconnecting traces were passivated with a 1-micron thick layer of silicon nitride to provide chemical and electrical insulation and microelectrode impedance was lowered utilizing electrode position of platinum black. The amplifier exhibited a nearly flat frequency response with high pass and low pass corner frequencies of 0.7 Hz and 50 kHz, respectively. The input referred noise over the 50 kHz bandwidth was 12-16 microVRMS, well below the magnitude of previously reported extracellular potentials. Crosstalk between neighboring channels resulted in an output signal below the amplifier noise level, even for relatively large extracellular potentials. Using this system, extracellular recording were demonstrated yielding typical peak-to-peak biopotentials of magnitude 0.9-2.1 mV and 100-400 microV for chick cardiac myocytes and rat spinal cord neurons, respectively. The key components of this extracellular recording system can be manufactured using industry standard thin film photolithographic techniques.

Amplifiers, Electronic

Design parameters of pulsed wave ultrasonic Doppler blood flowmeter.

Pulse wave Doppler techniques promise the ability to make more effective measurements of dynamic cardiovascular functions. Quantitative measurement of blood flow can be achieved by using the pulse wave Doppler system. This paper discusses the design parameters of the pulse wave Doppler blood flowmeter (PW Doppler) with respect to the physiological system.

Amplifiers, Electronic

Spatial aspects of reproduced sound in small rooms.

This paper reports on the influence of individual reflections on the auditory spatial aspects of reproduced sound. The sound field produced by a single loudspeaker positioned in a normal listening room has been simulated using an electroacoustical synthesis of the direct sound, 17 individual reflections and the reverberant field. The threshold of detection was measured using the method of adjustment for five reflections using three subjects for noise and speech. The thresholds have been measured for two simulated situations (1) a loudspeaker with a frequency independent directivity characteristics and frequency independent absorption coefficients of the room surfaces and (2) a loudspeaker with directivity similar to a standard two-way system and absorption coefficients according to measurements of real materials. The results have shown that subjects can reliably distinguish between timbre and spatial aspect of the sound field, that the spectral energy above 2 kHz of the individual reflection determines the importance of the reflection for the spatial aspects, and that only the first order floor reflection will contribute to the spatial aspects.

Amplifiers, Electronic