Rotating frame zeugmatography.

Abstract

The proton sensitivity obtainable at 5 MHz from a baby is sufficiently large to suggest the possibility of obtaining images with millimetre solution in seconds. Such goals present difficulties; for example, the high quality factor of the receiving coil necessary for good sensitivity limits the receiver bandwidth and leads to long pulse recovery times, and large, rapidly switched field gradients require power engineering. Solutions to these problems are being pursued at the National Institutes of Health (N.I.H.), where a high speed imaging system is under construction. For example, bandwidth and recovery time problems may be resolved with the aid of a low noise preamplifier with imaginary gain and Miller feedback, large gradients may be generated with a magnet comprising two rotatable hemispherical windings and switching of gradients may be eliminated by performing zeugmatography in the rotating frame. It is upon this latter aspect of the design that the present article concentrates.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D I Hoult. 1980-06-25. Rotating frame zeugmatography.. https://doi.org/10.1098/rstb.1980.0074

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Structure of the alpha-homo-DNA:RNA duplex and the function of twist and slide to catalogue nucleic acid duplexes.

High-resolution NMR studies of an alpha-homo-DNA:RNA duplex reveal the formation of a right-handed parallel-oriented helix. It differs significantly from a standard A- or B-type helix by a small twist value (26.2 degrees ), which leads to a helical pitch of 13.7 base pairs per helical turn, a negative inclination (-1.78 Angstrom) and a large x displacement (5.90 Angstrom). The rise (3.4 Angstrom) is similar to that found in B-DNA. The solution of this new helix structure has stimulated us to develop a mathematical and geometrical model based on slide and twist parameters to describe nucleic acid duplexes. All existing duplexes can be positioned within this landscape, which can be used to understand the helicalization process.

Magnetic Resonance Spectroscopy↗

15N NMR study of substituted 2-(phenylamino)-5-phenyl-1,3,4-oxadiazoles.

Substituted 2-(phenylamino)-5-phenyl-1,3,4-oxadiazoles were studied by 15N NMR spectroscopy. All signals were assigned on the basis of HMQC and HMBC experiments. Chemical shifts values were correlated with empirical Hammett parameters as well as with calculated electron densities and chemical shieldings.

Magnetic Resonance Spectroscopy↗

Functionalization of titanium oxide surfaces by means of poly(alkyl-phosphonates).

The use of a multiple attachment sites strategy is considered in order to improve the stability of monomolecular adlayers. The hypothesis was tested in the case of PEG-ylated compounds carrying phosphonate groups, known for their affinity toward titanium oxide surfaces. As a result, a new class of co- and terpolymers were synthesized by free-radical polymerization of three different monomers: dialkyl(methacryloyloxyalkyl)phosphonates, PEG methyl ether methacrylate, and/or butyl methacrylate monomers. Adlayers were formed following a simple dip-and-rinse protocol using diluted aqueous polymer solutions and were characterized by evaluating their thicknesses with variable angle spectroscopic ellipsometry (VASE) and their elemental compositions with X-ray photoelectron spectroscopy (XPS). The same techniques were used to determine changes of the adlayer as a function of exposure to electrolytes at different pH values and to monitor nonspecific protein adsorption upon serum exposures. The results indicated that the poly(alkyl-phosphonate)-based adlayers combine multiple site attachment of phosphonic groups and presentation of PEG side chains to the aqueous environment, resulting in both improved stability over a wide pH range in comparison to the tested reference surfaces and excellent resistance to protein adsorption when exposed to full human serum.

Magnetic Resonance Spectroscopy↗