Norwegian deep diving trials.

Abstract

In 1983 NUTEC, together with two diving companies, completed two dives with 12 divers (6 in each dive) to pressures equivalent to 350 m s.w., one dive lasted for 17 d, and the other, 24 d. The purpose of the dives was to demonstrate that the diving companies were prepared for diving to 300 m depth in the North Sea. No major medical or physiological problems arose during the dives, although all divers had minor symptoms of high pressure nervous syndrome during compressions. During decompression three decompression sickness incidents occurred, which involved pain only, and all were successfully treated. All divers went through comprehensive medical physiological examinations before and after the dives. No significant changes from values measured before diving have been found in the six divers who have so far been examined after diving, except that five of them were considerably more sensitive to CO2 after the dive than before. Several problems arose in connection with the divers' breathing equipment, thermal protection and communication, which need to be improved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Tønjum. 1984-01-07. Norwegian deep diving trials.. https://doi.org/10.1098/rstb.1984.0015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A dual-respiration chamber system with automated calibration.

This study characterizes respiration chambers with fully automated calibration. The system consists of two 14-m3 pull-type chambers. Care was taken to provide a friendly environment for the subjects, with the possibility of social contact during the experiment. Gas analysis was automated to correct for analyzer drift and barometric pressure variations and to provide ease of use. Methods used for checking the system's performance are described. The gas-analysis repeatability was within 0.002%. Results of alcohol combustion (50-350 ml/min CO2) show an accuracy of 0.5 +/- 2.0 (SD) % for O2 consumption and -0.3 +/- 1.6% for CO2 production for 2- to 24-h experiments. It is concluded that response time is not the main factor with respect to the smallest practical measurement interval (duration); volume, mixing, gas-analysis accuracy, and levels of O2 consumption and CO2 production are at least equally important. The smallest practical interval was 15-25 min, as also found with most chamber systems described in the literature. We chose to standardize 0.5 h as the minimum measurement interval.

Atmosphere Exposure Chambers