PubMed Health⌕ Search

PubMed · 6169596

[Hemostasis disorders after transfusions].

Abstract

Disturbances of haemostasis caused immunologically and non-immunologically were observed after transfusion of blood and blood derivatives. Transfusion of heparin blood increased the bleeding susceptibility only in case of pre-existing high-degree defects of haemostasis or if they were performed as massive or exchange transfusions. Massive transfusions with blood stored for a long time will induce complex defects. Under intensive substitution therapy of haemophilia A the so-called paradoxical bleeding will occur in spite of a high factor VIII level. These bleedings are supposed to be disturbances of the thrombocyte function and are caused by fibrin(ogen) derivatives. Post-transfusional thrombocytopenias may be brought to remission by repeated plasmapheresis. Factor specific inhibitory bodies will appear after substitution in a small percentage of haemophilic patients. 5 to 7 days after the onset of therapy an anamnestic reaction can be observed as a titre increase by leaps. Usually, the inhibitory titre will decrease to a mostly low basal value in the course of three to five months. The therapy with cyclophosphamide simultaneously started with the substitution will more frequently prevent the anamnestic reaction or reduce it. Titres with more than 5 units cannot be overcome at the beginning even by higher concentrations of preparations. The substitution therapy should be preceded by exchange transfusions or plasmapheresis of up to 25 units. With still higher titres only procedures of inhibitor-bypassing are possible with factor VIII preparations of animal origin or better with activated prothrombin complex preparations, such as FEIBA. Recent reports give evidence that permanent substitution with factor VIII concentrates at a highest dosage can eliminate the production of inhibitors completely.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Weissbach, M Domula, H Lenk. 1981. [Hemostasis disorders after transfusions].. https://pubmed.ncbi.nlm.nih.gov/6169596/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Molecular characterization of an Italian patient with plasminogen deficiency and ligneous conjunctivitis.

Plasminogen deficiency is a rare disease characterized by ligneous conjunctivitis and infections. We observed a 3-year-old Italian boy presenting ligneous conjunctivitis and low plasma levels of plasminogen. Twenty-three different mutations on the PLG gene have been reported to date, but mutation analysis had been troublesome for the presence of highly homologous genes. The aim of the study was to identify the underlying mutation avoiding coamplification of unwanted genetic materials using a long polymerase chain reaction strategy, instead of the previously reported subcloning methods. By this simple strategy the complete sequence analysis of PLG gene was performed, and a previously reported missense homozygous mutation (K19E) was identified.

Blood Coagulation Disorders↗

Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography.

BACKGROUND: Reagent-supported thromboelastometry with the rotation thrombelastography (e.g. ROTEM) is a whole blood assay that evaluates the visco-elastic properties during blood clot formation and clot lysis. A hemostatic monitor capable of rapid and accurate detection of clinical coagulopathy within the resuscitation room could improve management of bleeding after trauma. OBJECTIVES: The goals of this study were to establish whether ROTEM correlated with standard coagulation parameters to rapidly detect bleeding disorders and whether it can help to guide transfusion. METHODS: Ninety trauma patients were included in the study. At admission, standard coagulation assays were performed and ROTEM parameters such as clot formation time (CFT) and clot amplitude (CA) were obtained at 15 min (CA(15)) with two activated tests (INTEM, EXTEM) and at 10 min (CA(10)) with a test analyzing specifically the fibrin component of coagulation (FIBTEM). RESULTS: Trauma induced significant modifications of coagulation as assessed by standard assays and ROTEM. A significant correlation was found between prothrombin time (PT) and CA(15)-EXTEM (r = 0.66, P < 0.0001), between activated partial thromboplastin time and CFT-INTEM (r = 0.91, P < 0.0001), between fibrinogen level and CA(10)-FIBTEM (r = 0.85, P < 0.0001), and between platelet count and CA(15)-INTEM (r = 0.57, P < 0.0001). A cutoff value of CA(15)-EXTEM at 32 mm and CA(10)-FIBTEM at 5 mm presented a good sensitivity (87% and 91%) and specificity (100% and 85%) to detect a PT > 1.5 of control value and a fibrinogen less than 1 g L(-1), respectively. CONCLUSIONS: ROTEM is a point-of-care device that rapidly detects systemic changes of in vivo coagulation in trauma patients, and it might be a helpful device in guiding transfusion.

Blood Coagulation Disorders↗