Reversible EOL-indicator: a new cause for low pacemaker rate.

Abstract

A case is presented in which a new cause for decrease in pacemaker rate was encountered: six months after implantation of a Medtronic 5967 pacemaker, the first routine check-up revealed a rate of 62.5 ppm instead of 70 ppm. After application of a magnet, all measurements returned to normal. The cause for this phenomenon, which could not be attributed to battery depletion or oversensing, was probably a change of state of the flip-flop which is responsible for the sudden rate drop of 10% which serves as the end-of-life (EOL)-indicator in this pacemaker. This change of state may result from a very short decrease of power supply voltage during shipment or at the time of implant, and is fully and permanently reversible by performance of the magnet test. In order to prevent unnecessary pacemaker explants, future pacemaker circuits should be redesigned to eliminate the effect of very short voltage changes. Meanwhile, a routine magnet test should be performed immediately after implantation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W Scheibelhofer, J Kaliman, A Laczkovics, H Mayr, H Weber, F Kaindl. 1983. Reversible EOL-indicator: a new cause for low pacemaker rate.. https://doi.org/10.1111/j.1540-8159.1983.tb05325.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Hazard surveillance for industrial magnetic fields: I. Walkthrough survey of ambient fields and sources.

A walkthrough survey method was developed for measuring ambient magnetic fields (MFs) in industrial facilities as the first stage in hazard surveillance. This survey was designed to measure the mean and peak MF magnitudes at extremely low frequencies (ELFs), so that factories could be ranked by MF levels and prioritized for subsequent personal exposure monitoring. Sixty-two facilities from 13 Standard Industrial Classifications (SICs) with the highest monthly electric power usage were surveyed. To measure ambient MFs, a structured walkthrough survey with a special emphasis on workstations was conducted with an EMDEX-II meter in continuous operation, while MF sources were noted. The broadband MF data (40-800Hz) for each facility were summarized with the geometric mean (GM) and the average of the five highest readings (Hi-5). The range of the GM magnetic field magnitude was 0.04-1.61microT, where the maximum was measured at a steel mill operating large electric furnaces. Maximum values for specific sources were highly variable across and within facilities (Hi-5 range: 1.0-530 microT). Chemical and Allied Products (SIC 28) and Primary Metal Products (SIC 33) had facilities with GM and Hi-5 magnetic fields greater than any of the other industrial categories. However, the SIC categories were found to be poor predictors of the ambient MF in this sample of factories. A weak relationship was found between the facility-specific monthly electric power consumption and the GM magnetic field magnitude, but confidence limits were too broad to make meaningful exposure predictions from electric power data. Overall, 89% of the GMs were at or below 0.4 microT, consistent with most other studies that collected industrial MF exposure data. The walkthrough survey is a practical way of measuring ambient MFs in a large number of workplaces, and should be evaluated with personal measurements as a screening method for hazard surveillance.

Electric Power Supplies↗

Feasibility of using the automatic generating system for quartz watches as a leadless pacemaker power source.

An automatic power-generating system (AGS) which converts kinetic energy into electric energy for quartz watches was tested as a power source for implantable cardiac pacemakers. An automatic power-generating mechanism and a capacitor (0.33 F) were removed from a quartz watch (SEIKO) and encapsulated in a polyvinyl case. Characteristics of the AGS were investigated by acceleration equipment. The capacitor in the AGS was charged to 2.0 V (0.66 J) by placing it on the equipment for about 30 minutes. The equipment has a 2 Hz cycle and generates +/- 1.7 G at the end of each half cycle. The AGS (fully charged to 2.0 V) was used as the power source for a pulse generator circuit built using commercially available CMOS IC. The circuit generated pulses of 0.5 ms width at 1 Hz (60 pulses min-1). The voltage of the AGS was maintained at 1.6 V while it was being charged by the accelerations. The generator supplied pulses of 0.75 V, 1.47 mA through a 510 omega load. With fully charged AGS, the generator was also used to pace a mongrel dog's heart at 140 beats min-1 for 60 minutes. During pacing, the AGS supplied 420 mJ to the circuit and the cardiac muscle. The AGS was placed on the right ventricular wall of the mongrel dog under anaesthesia. Energy of 80 mJ is stored in a capacitor by the heart beating at about 200 beats/min for 30 minutes. Thus the AGS generated 13 microJ per heart beat. This result suggests that the AGS may supply enough energy for use in a cardiac pacemaker.

Electric Power Supplies↗