PubMed HealthSearch

PubMed · 62425

A standardized technique for efficient platelet and leukocyte collection using the Model 30 Blood Processor.

Abstract

The Model 30 Blood Processor is a safe and simple means of harvesting blood cell components. Presently cell collection depends on a visual assessment by the operator of the indistinct boundaries of cell fractions. To determine when each cell component could best be harvested, serial samples were taken from the output port at fixed intervals anf the results of counts and differentials were graphed and tabulated. Studies in normal donors were done using acid-citrate-dextrose (ACD), 2 per cent sodium citrate in 6 per cent hydroxyethyl starch (HES), or heparin as anticoagulants. There was considerable overlap between the latter part of the platelet band, the leukocyte band and the rising hematocrit with all three anticoagulants. Normally functional lymphocytes could be harvested efficiently (approximately 80%) using ACD or heparin. Platelets could be harvested from ACD very efficiently (approximately 90%). Granulocytes could not be harvested from ACD (less than 10%) since they were dispersed in the red blood cell (RBC) layer. Using HES, granulocytes could be harvested efficiently (approximately 70%) by extending collection into the RBC layer. Based on these data, a standard technique for cell collection has been devised. The flow rate is slowed to 20 ml/min and collection is carried 30 ml (90 seconds at a rate of 20 ml/min) for platelets. The RBC loss is approximately 6 to 8 and 2 to 3 ml/pass respectively. These studies indicate that the Model 30 is a highly efficient apparatus for blood cell separation, but the volume of blood processed is limited by the intermittent blood flow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Aisner, C A Schiffer, J H Wolff, P H Wiernik. A standardized technique for efficient platelet and leukocyte collection using the Model 30 Blood Processor.. https://doi.org/10.1046/j.1537-2995.1976.16577039299.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of platelet count and platelet protein methods for determination of platelet MAO activity.

Platelet monoamine oxidase (MAO) activity in 10 normal volunteers was studied as a function of platelet protein or electronically-determined platelet counts. Comparisons of the two methods were made for samples assayed on the same day as well as one week later. The MAO activities resulting from both methods were significantly correlated and reproducible but the results of the platelet count method were, in most instances, slightly but significantly more reliable than the platelet protein method. The relevance of these results to the controversy concerning platelet MAO activity in schizophrenia is discussed.

Blood Cell Count

[Thrombokinetics].

Explore the source record for details and available documents.

Blood Cell Count