PubMed Health⌕ Search

PubMed · 6358096

Pilot epidemiological study in Taegu, Korea.

Abstract

One hundred and seven normal Korean subjects were interviewed with the Korean translation of the Diagnostic Interview Schedule as part of a pilot epidemiological study in Taegu, Korea. A surprisingly high number of these subjects met criteria for the DSM diagnosis made by the computer scored interview. Psychiatric residents reinterviewed twelve subjects who were computer diagnosed as having psychopathology. Comparisons of clinical diagnoses vs. computer diagnoses are presented and discussed. The National Institute of Mental Health of the United States has embarked on exciting studies of the epidemiology of mental disorders. In order to accurately measure the prevalence of mental disorders in normal population, the NIMH contracted for the creation of a diagnostic interview schedule. Lee Robins, Ph.D. of the Washington University School of Medicine, created the National Institute of Mental Health Diagnostic Interview Schedule. Currently it is in Version III. Our study was done with Version II, which had been translated into the Korean language. A report of the validity of the DIS in English has been published by Robins. (5) In addition, there have been review articles by Hedlund and Viewig. (2) The DIS has been patterned after the DSM III so that when the interview is correctly done, criteria for the diagnosis according to DSM III, the Research Diagnostic Criteria, and the Renard Hospital Diagnostic Criteria are within the questions asked during the interview. In English, our experience has shown that Version II takes approximately 45 minutes to an hour and a half. In Asian languages, our experience shows that the interview takes somewhat longer. (10).(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Yamamoto, B J Kang. 1983. Pilot epidemiological study in Taegu, Korea.. https://doi.org/10.1177/002076408302900407

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Use of a screening device for sleep apnea in clinical practice].

About 2-4% of adults suffer from obstructive sleep apnea (OSA), which is the most common sleep-related breathing disorder (SRBD). Repetitive obstructions of the upper airway mean that it is associated with hypertension and an elevated cardio- and cerebrovascular morbidity, which can be lowered by means of effective therapy. These patients cannot be treated correctly unless they are identified early in the course of the condition. Therefore, this study evaluated the use of the microMESAM screening device (known up to December 2005 as the "ApneaLink") in 61 patients in whom SRBD was suspected. The device proved reliable and practical in application.

Diagnosis, Computer-Assisted↗

Computer-aided diagnosis for improved detection of lung nodules by use of posterior-anterior and lateral chest radiographs.

RATIONALE AND OBJECTIVES: We developed a computerized scheme for detection of lung nodules in the lateral views of chest radiographs, in order to improve the overall performance in combination with the computer-aided diagnostic (CAD) scheme for posterior-anterior (PA) views. MATERIALS AND METHODS: We used 106 pairs of PA and lateral views of chest radiographs (122 lung nodules) for development of the CAD scheme. In the CAD scheme for lateral views, initial candidates of lung nodules were identified by use of a nodule enhancement filter based on the edge gradients. Thirty-four image features extracted from the original and the nodule-enhanced images were used for the rule-based scheme and for artificial neural networks (ANNs) for removal of some false-positive candidates. The computer performance was evaluated with a leave-one-case-out test method for ANNs. For PA views, we used the existing CAD scheme, which was trained with one-half of 924 chest images and then tested with the remaining images. RESULTS: When the CAD scheme was applied only to PA views, the sensitivity in the detection of lung nodules was 70.5%, with 4.9 false positives per image. Although the performance of the computerized scheme for lateral views was relatively low (60.7% sensitivity with 1.7 false positives per image), the overall sensitivity (86.9%) was improved (6.6 false positives per two views), because 20 (16.4%) of the 122 nodules were detected only on lateral views. CONCLUSIONS: The CAD scheme by use of lateral-view images has the potential to improve the overall performance for detection of lung nodules on chest radiographs when combined with a conventional CAD scheme for standard PA views.

Diagnosis, Computer-Assisted↗

Improvement of the detection of myocardial ischemia thanks to information technologies.

BACKGROUND: The standard 12-lead ECG remains one of the basic investigations for the early detection and assessment of acute coronary syndromes. It is easy to perform, anywhere and anytime, and can be digitally transmitted within minutes to an emergency medical service for remote advice and triage. But the conventional ST-segment deviation criteria are of limited diagnostic accuracy. The purpose of this study is to investigate how much the use of computerized ECG techniques based on the measurement of the serial spatiotemporal ECG changes could improve the detection accuracy of transmural myocardial ischemia. METHODS: We considered the serial changes of continuous 12-lead ECGs of 90 patients undergoing elective percutaneous coronary angioplasty (PTCA) recorded during balloon inflation as an experimental model of ECG changes induced by coronary artery occlusion. The spatiotemporal ECG changes were measured according to the CAVIAR method and assessed by multivariate discriminant analysis in reference to serial changes of control recordings and standard ECG criteria. RESULTS: The diagnostic accuracy of the CAVIAR criteria for ischemia detection was 97%, with sensitivity of 98% and specificity of 96%, whereas the diagnostic accuracy of the conventional ST-segment criteria was 74%, with sensitivity of 60% and specificity of 88%. The increase of overall performance was obtained for all the occlusion locations. CONCLUSIONS: Computer-assisted quantitative serial ECG analysis, taking into account the spatiotemporal changes of the QRS and T waves, would provide the physician with additional information for significantly improving the detection of transmural myocardial ischemia.

Diagnosis, Computer-Assisted↗