A photodiode array x-ray imaging system for digital angiography.

Abstract

A line scanning imaging system that can be used to make low-noise x-ray images to detect low-contrast structure is described. The system makes use of a 1024-element, self-scanning, photodiode array (Reticon RL 1024S) optically coupled to an x-ray image intensifier tube. Low-noise images are obtained by imaging only small areas of interest at a time to reduce the noise resulting from the detection of scattered radiation, and by making use of the very large dynamic range (8000:1) solid-state photodetector. Some performance characteristics of the diode array system are discussed. It was found that while sensitivities of individual elements differed by up to +/- 15% from the average, they could be corrected with a precision of 0.02% to 0.04% of the maximum signal. The limiting spatial resolution of the system in the direction of the diode array was 2.0 cycles/mm, limited by the image intensifier. The system linearity was studied by measuring the attenuation of a monoenergetic x-ray beam by Plexiglas. The measured attenuation agreed with the expected exponential decrease over a range of approximately 1000 to within experimental error. The imaging capabilities of the system were demonstrated by imaging an angiographic phantom consisting of an iodine-filled tube with an asymmetric 20% stenosis. The stenosis was oriented on the tube surface furthermost from the detector resulting in an image with a 2% radiographic contrast change but no decrease of the tube width. The stenosis was clearly imaged using a temporal subtraction technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I A Cunningham, A Fenster. A photodiode array x-ray imaging system for digital angiography.. https://doi.org/10.1118/1.595630

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transhepatic vascular access for diagnostic and interventional procedures: techniques, outcome, and complications.

Early or multiple cardiac catheterizations may result in occlusion of the femoral veins prohibiting their use. The internal jugular or sub-clavian approach may be an appropriate alternative. However, these approaches may not be suitable in patients with surgical interruption of the superior vena cava. In other patients, they may not allow easy access to certain areas of the heart. The transhepatic approach is an important alternative route for performing cardiac catheterization and interventions. Depending on the planned procedure, it may be the preferred route to perform the cardiac catheterization even in the presence of patent femoral veins. The indications, technical details and potential complications of this approach are discussed.

Angiography↗

Embolization for a bleeding pelvic fracture in a patient with persistent sciatic artery.

Emergency embolization for a bleeding pelvic fracture was performed in a patient with persistent sciatic artery, a rare anatomic variation in which the internal iliac artery continues to the popliteal artery. Successful hemostasis was achieved without complications by means of selective catheterization into each branch of the internal iliac artery. Awareness of this unusual vascular anatomy is critically important to avoid serious complication of emergency embolization.