PubMed HealthSearch

PubMed · 6379235

[Pacemaker electrodes].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Togawa. 1983. [Pacemaker electrodes].. https://pubmed.ncbi.nlm.nih.gov/6379235/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Protamine-sensitive polymer membrane electrode: characterization and bioanalytical applications.

A polymeric membrane electrode that exhibits significant and analytically useful potentiometric response to submicromolar levels of the heparin antagonist, protamine, is reported. The sensor is prepared by incorporating a lipophilic cation exchanger, potassium tetrakis(4-chlorophenyl)borate (KTpClPB) (at 1 wt%), within a specially formulated polymer membrane composed of 33 wt% 2-nitrophenyl octyl ether (2-NPOE), and 66 wt% poly(vinyl chloride) (PVC). When the polymer film is mounted in an appropriate electrode body, the resulting membrane electrode responds reproducibly to protamine via a nonequilibrium quasi-steady-state change in the phase boundary potential at the membrane/sample interface. Such response can be used to directly monitor, via classical potentiometric titrations, the binding between protamine and a variety of native (porcine and beef) as well as low-molecular-weight heparins. Scatchard analysis of the EMF titration data provides binding constants and stoichiometries for protamine-heparin interactions. The electrode can be further used to follow the enzymatic digestion of protamine by trypsin. In the presence of a given level of protamine, initial rates of potential decrease (-dE/dt) are shown to be linearly related to trypsin activity in solution over the range of 0-130 units/ml. The speed and simplicity of the protamine sensor make it an attractive alternative to classical methods for studying the interaction of protamine with other biologically important macromolecules as well as the proteolytic activity and reaction kinetics of trypsin.

Electrodes

Construction of a diflunisal ion sensor and its use in automated flow-injection methods for assay, content uniformity, and dissolution studies of formulations.

A diflunisal ion selective electrode of the PVC membrane type with an ion-exchanger consisting of the tetraheptylammonium-diflunisal ion pair is described. The sensor exhibits a rapid, near-Nernstian, selective response to diflunisal anion in the pH range 7-10, with a (batch) detection limit of 1 x 10(-5) M. The ion sensor was used as a flow detector in an automated flow-injection analyzer to develop routine methods for assays (concentration range 1-50 x 10(-4) M, (flow) detection limit 2.6 x 10(-5) M), content uniformity, and dissolution studies of diflunisal formulations. No serious interference from common ions and tablet excipients was found, and the drug can be directly determined in colored samples without separation steps. Fourty measurements can be performed automatically per hour with a precision of 0.5-1.8% relative standard deviation. The automated method for the dissolution test provides a complete dissolution profile by the end of the experiment. Using the constructed ion sensor, the intramolecular hydrogen bonding of the diflunisal anion was studied, thereby revealing a new application of ion sensor potentiometry.

Electrodes

Technique of simultaneous recording of EMG from various extraocular muscles under EOG control.

With this technique simultaneous recording of EMG is shown from various extra-ocular muscles. Electrodes are applied in the muscles during surgical procedures and recordings are performed without discomfort in the following days. The electrical signals are acquired at large bandwidth, and various off-line elaborations are possible. Preliminary results as well as technical details are presented.

Electrodes