PubMed Health⌕ Search

PubMed · 6387823

[Stereotaxic irradiation with a linear accelerator].

Abstract

At least two fundamental requirements must subsist for every stereotaxic radiotherapy treatment: 1) a capacity to administer extremely high doses of radiation to small areas which have been precisely defined in three dimensions; 2) the presence of a steep gradient between adjacent isodose curves so that damage to the tissues close to the target may be reduced to the minimum. The authors have built a special stereotaxic device for the fixing of the head of the patient (together with the chosen intracranial target), once the indispensable neuroradiological evaluations and bioptic controls have been effected, at the isocenter of a linear accelerator (Varian Clinac 4). Once the dimensions of the collimator have been chosen in accordance with the volume and the three dimensional conformation of the target and the dose to be administered has been decided upon in accordance with the histological nature of the lesion, both the linear accelerator and the patient are rotated about the isocenter of the therapy unit. It this way it is possible to reach extremely high dosages with very steep isodose gradients, centered exclusively upon the target ("gamma knife"). The procedure employed is described in full. The dosimetric evaluations which preceded the use of the set-up in clinical practice are illustrated as well. The advantages that this technique offers when compared with interstitial brachytherapy and/or Leksell's radiosurgical procedures are stressed. The described procedure, which is entirely bloodless and thus applicable also to high vascularized lesions, has so far been used in a limited series of cases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R C Avanzo, G Chierego, C Marchetti, F Pozza, F Colombo, A Benedetti, A Zanardo. 1984. [Stereotaxic irradiation with a linear accelerator].. https://pubmed.ncbi.nlm.nih.gov/6387823/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A penalized likelihood approach to magnetic resonance image reconstruction.

Currently, images acquired via magnetic resonance imaging (MRI) and functional magnetic resonance imaging (fMRI) technology are reconstructed using the discrete inverse Fourier transform. While computationally convenient, this approach is not able to filter out noise. This is a serious limitation because the amount of noise in MRI and fMRI can be substantial. In this paper, we propose an alternative approach to reconstruction, based on penalized likelihood methodology. In particular, we focus on non-linear shrinkage estimators and show that this approach achieves a great reduction in integrated mean squared error (IMSE) of the estimated image with respect to the currently used estimator. This approach is extremely fast and easy to implement computationally. In addition, it can be combined with various alternative approaches to MR image reconstruction and can be easily adapted to other, non-MRI contexts, in which the observed data and the quantities of interest are related via a linear transform.

Brain Diseases↗